Literature DB >> 14559334

Inter-rater and intra-rater reliability of subchondral bone and cartilage thickness measurement from MRI.

Chris A McGibbon1.   

Abstract

MRI is often used to visualize and quantify the articular cartilage layer of load bearing joints affected by degenerative diseases, such as osteoarthritis (OA). Although the role played by the subchondral bone in the etiology and/or progression of OA may be important, the ability to visualize and quantify subchondral bone with MRI has received little attention. In this report we examined the inter-rater and intra-rater reliability of subchondral bone and cartilage thickness measurements from MR images of cadaver femoral head specimens. A 3D-SPGR pulse sequence tuned to eliminate chemical shift artifact through phase cancellation was used to image the specimens. Three raters manually segmented four specimens on two different occasions. Subchondral bone and cartilage thickness measurements were calculated from the segmented images. Inter-rater and intra-rater reliabilities were very high (>.98) for both cartilage and subchondral bone thickness measurements. We conclude that subchondral bone thickness can be measured as reliably as cartilage thickness from MR images.

Entities:  

Mesh:

Year:  2003        PMID: 14559334     DOI: 10.1016/s0730-725x(03)00107-3

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  4 in total

1.  MRI of the temporo-mandibular joint: which sequence is best suited to assess the cortical bone of the mandibular condyle? A cadaveric study using micro-CT as the standard of reference.

Authors:  Christoph A Karlo; Raphael Patcas; Thomas Kau; Helmut Watzal; Luca Signorelli; Lukas Müller; Oliver Ullrich; Hans-Ulrich Luder; Christian J Kellenberger
Journal:  Eur Radiol       Date:  2012-02-10       Impact factor: 5.315

2.  Subchondral bone and cartilage thickness from MRI: effects of chemical-shift artifact.

Authors:  Chris A McGibbon; Jenny Bencardino; William E Palmer
Journal:  MAGMA       Date:  2003-02       Impact factor: 2.310

Review 3.  Osteoarthritis: symptoms, signs and source of pain.

Authors:  W F Kean; R Kean; W W Buchanan
Journal:  Inflammopharmacology       Date:  2004       Impact factor: 4.473

4.  Accuracy verification of magnetic resonance imaging (MRI) technology for lower-limb prosthetic research: utilising animal soft tissue specimen and common socket casting materials.

Authors:  Mohammad Reza Safari; Philip Rowe; Arjan Buis
Journal:  ScientificWorldJournal       Date:  2012-04-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.