Biocompatibility of a physiological pressure sensor.

Chao Yang1, Chunfeng Zhao, Lester Wold, Kenton R Kaufman.   

Abstract

A newly developed fiber optic micropressure sensor was evaluated for biocompatibility using the International Organization for Standardization (ISO) test standard 10993-6. The test material and an inert control (fused silica glass) were tested in New Zealand white rabbits. Four test specimens were implanted in the paravertebral muscles on one side of the spine about 2-5 cm from the mid-line and parallel to the spinal column. Similarly, four control specimens were implanted on the opposite side. The implantation periods were 1, 4, and 12 weeks to ensure a steady state biological tissue response. Four animals were tested at each time period. Macroscopic and microscopic observations were performed to compare the biological reactions between the test and control materials. There was an inflammatory reaction at 1 week which subsided at 4 weeks. There was fibrous tissue growth near the implant that also decreased over time. Most importantly, there was no significant difference in the biological response between the test and control materials. Therefore, we conclude that the pressure microsensor is biocompatible.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14558998     DOI: 10.1016/s0956-5663(03)00131-3

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  7 in total

1.  Biocompatibility studies of natural rubber latex from different tree clones and collection methods.

Authors:  Juliana Ferreira Floriano; Lígia Souza Lima Silveira da Mota; Edson Luiz Furtado; Victor José Vieira Rossetto; Carlos F O Graeff
Journal:  J Mater Sci Mater Med       Date:  2013-11-08       Impact factor: 3.896

2.  Use of a Poroelastic Model to Predict Intramuscular Pressure.

Authors:  D A Morrow; G M Odegard; K R Kaufman
Journal:  Poromechanics V (2013)       Date:  2013-07-10

3.  Performance characteristics of a new generation pressure microsensor for physiologic applications.

Authors:  Patrick S Cottler; Whitney R Karpen; Duane A Morrow; Kenton R Kaufman
Journal:  Ann Biomed Eng       Date:  2009-06-03       Impact factor: 3.934

Review 4.  Optical Fibre Pressure Sensors in Medical Applications.

Authors:  Sven Poeggel; Daniele Tosi; DineshBabu Duraibabu; Gabriel Leen; Deirdre McGrath; Elfed Lewis
Journal:  Sensors (Basel)       Date:  2015-07-15       Impact factor: 3.576

Review 5.  Recent Progress of Miniature MEMS Pressure Sensors.

Authors:  Peishuai Song; Zhe Ma; Jing Ma; Liangliang Yang; Jiangtao Wei; Yongmei Zhao; Mingliang Zhang; Fuhua Yang; Xiaodong Wang
Journal:  Micromachines (Basel)       Date:  2020-01-01       Impact factor: 2.891

Review 6.  Development of clinically relevant implantable pressure sensors: perspectives and challenges.

Authors:  Ingelin Clausen; Thomas Glott
Journal:  Sensors (Basel)       Date:  2014-09-22       Impact factor: 3.576

7.  Properties of Fibrous Concrete Made with Plastic Optical Fibers from E-Waste.

Authors:  Zbigniew Suchorab; Małgorzata Franus; Danuta Barnat-Hunek
Journal:  Materials (Basel)       Date:  2020-05-25       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.