Literature DB >> 14557357

Predictors of improved renal function after percutaneous stent-supported angioplasty of severe atherosclerotic ostial renal artery stenosis.

Thomas Zeller1, Ulrich Frank, Christian Müller, Karlheinz Bürgelin, Lutz Sinn, Hans-Peter Bestehorn, Nancy Cook-Bruns, Franz-Josef Neumann.   

Abstract

BACKGROUND: Percutaneous stent-supported angioplasty is a treatment option for atherosclerotic ostial renal artery stenosis. Improvement of renal function by such intervention, however, is controversial and thought to be limited to specific subsets, such as nondiabetic patients and bilateral stenoses. In this prospective study, we investigated predictors for improvement of renal function and blood pressure after renal artery stent placement. METHODS AND
RESULTS: The study included 215 consecutive patients with ostial renal artery stenosis of > or =70% diameter stenosis undergoing stent-supported angioplasty. The primary end point was decrease in serum creatinine concentration at 1 year; the secondary end point, decrease in average mean arterial blood pressure assessed by 24-hour monitoring. One-year follow-up was complete in 191 surviving patients. In 52% (99/191) of the patients, serum creatinine concentration decreased during 1-year follow-up. Median serum creatinine concentration dropped significantly from 1.21 mg/dL (quartiles: 0.92, 1.60 mg/dL) at baseline to 1.10 mg/dL (quartiles: 0.88, 1.50 mg/dL) at 1 year (P=0.047). On average, mean arterial blood pressure decreased significantly, from 102+/-12 mm Hg (mean+/-SD) at baseline to 92+/-10 mm Hg at 1 year (P<0.001). Significant independent predictors of improved renal function were baseline serum creatinine (odds ratio [95% CI], 2.58 [1.35 to 4.94], P=0.004) and left ventricular function (OR 1.51 [1.04 to 2.21], P=0.032). Female sex, high baseline mean blood pressure, and normal renal parenchymal thickness were independent predictors for decreased mean blood pressure.
CONCLUSIONS: Stent-supported angioplasty for severe ostial renal artery stenosis improves renal function and blood pressure in a broader spectrum of patients than previously thought.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14557357     DOI: 10.1161/01.CIR.0000095786.44712.2A

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  31 in total

Review 1.  Management of atherosclerotic renovascular disease: the effect of renal artery stenting on renal function and blood pressure.

Authors:  Kosmas I Paraskevas; Despina Perrea; Despina D Briana; Christos D Liapis
Journal:  Int Urol Nephrol       Date:  2006       Impact factor: 2.370

Review 2.  Update on intervention versus medical therapy for atherosclerotic renal artery stenosis.

Authors:  Albeir Y Mousa; Ali F AbuRahma; Joseph Bozzay; Mike Broce; Mark Bates
Journal:  J Vasc Surg       Date:  2015-06       Impact factor: 4.268

3.  Coronary-like revascularization for atherosclerotic renal artery stenosis--results in 181 consecutive patients.

Authors:  P Lanzer; R Weser; C Prettin
Journal:  Clin Res Cardiol       Date:  2006-08-16       Impact factor: 5.460

Review 4.  Diagnosis and management of atherosclerotic renal artery stenosis: improving patient selection and outcomes.

Authors:  Christopher J White; Jeffrey W Olin
Journal:  Nat Clin Pract Cardiovasc Med       Date:  2009-03

Review 5.  Renovascular hypertension in 2007: where are we now?

Authors:  Stephen C Textor
Journal:  Curr Cardiol Rep       Date:  2007-11       Impact factor: 2.931

Review 6.  [Current management of renal artery stenosis].

Authors:  T Lenz
Journal:  Internist (Berl)       Date:  2013-12       Impact factor: 0.743

Review 7.  Evaluation and approach to treatment of renal artery stenosis in patients with diabetic nephropathy.

Authors:  Jose A Silva
Journal:  Curr Diab Rep       Date:  2008-12       Impact factor: 4.810

Review 8.  Diagnosis and therapy of atheromatous renal artery stenosis.

Authors:  Masayuki Tanemoto
Journal:  Clin Exp Nephrol       Date:  2013-03-26       Impact factor: 2.801

Review 9.  [Hypertension in patients with renal artery stenosis].

Authors:  A Voiculescu; L C Rump
Journal:  Internist (Berl)       Date:  2009-01       Impact factor: 0.743

10.  RADAR - A randomised, multi-centre, prospective study comparing best medical treatment versus best medical treatment plus renal artery stenting in patients with haemodynamically relevant atherosclerotic renal artery stenosis.

Authors:  Uwe Schwarzwälder; Michael Hauk; Thomas Zeller
Journal:  Trials       Date:  2009-07-27       Impact factor: 2.279

View more