Literature DB >> 14553809

Adaptive clutter filtering for ultrasound color flow imaging.

Yang Mo Yoo1, Ravi Managuli, Yongmin Kim.   

Abstract

In this article, we present an adaptive clutter rejection method for selecting different clutter filters in ultrasound color flow imaging. A single clutter filter is typically used to reject the clutter. Because the clutter characteristics vary in both space and time, the single clutter filter approach has difficulty in providing optimum clutter rejection in ultrasound images. To achieve more accurate velocity estimation, we have developed a method to select a clutter filter adaptively at each location in an image from a set of predefined filters. Selection criteria have been developed based on the underlying clutter characteristics and the properties of various filters (e.g., minimum-phase finite impulse response, projection-initialized infinite impulse response and polynomial regression). We have incorporated our adaptive clutter rejection method in an ultrasound system. We have found that our adaptive method can reduce the mean absolute error between the estimated and true flow velocities significantly compared with the conventional methods, in which a single clutter filter is used throughout the entire image. With in vivo abdominal data, we obtained an average gain of 5.0 dB in signal-to-clutter ratio (SCR), compared with the conventional method. These preliminary results indicate that the proposed adaptive method could improve the accuracy of flow velocity estimation in ultrasound color flow imaging through the improvement in SCR and the reduction in bias.

Entities:  

Mesh:

Year:  2003        PMID: 14553809     DOI: 10.1016/s0301-5629(03)01014-7

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

1.  Microvascular Flow Imaging of Residual or Recurrent Hepatocellular Carcinoma after Transarterial Chemoembolization: Comparison with Color/Power Doppler Imaging.

Authors:  Hyo Jin Kang; Jeong Min Lee; Sun Kyung Jeon; Hwaseong Ryu; Jeongin Yoo; Jae Keun Lee; Joon Koo Han
Journal:  Korean J Radiol       Date:  2019-07       Impact factor: 3.500

2.  Super-resolution ultrasound imaging method for microvasculature in vivo with a high temporal accuracy.

Authors:  Jaesok Yu; Linda Lavery; Kang Kim
Journal:  Sci Rep       Date:  2018-09-17       Impact factor: 4.379

Review 3.  Clutter suppression in ultrasound: performance evaluation and review of low-rank and sparse matrix decomposition methods.

Authors:  Naiyuan Zhang; Md Ashikuzzaman; Hassan Rivaz
Journal:  Biomed Eng Online       Date:  2020-05-28       Impact factor: 2.819

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.