Literature DB >> 14552576

A comparison of exact and approximate adjoint sensitivities in fluorescence tomography.

M J Eppstein1, F Fedele, J Laible, C Zhang, A Godavarty, E M Sevick-Muraca.   

Abstract

Many approaches to fluorescence tomography utilize some form of regularized nonlinear least-squares algorithm for data inversion, thus requiring repeated computation of the Jacobian sensitivity matrix relating changes in observable quantities, such as emission fluence, to changes in underlying optical parameters, such as fluorescence absorption. An exact adjoint formulation of these sensitivities comprises three terms, reflecting the individual contributions of 1) sensitivities of diffusion and decay coefficients at the emission wavelength, 2) sensitivities of diffusion and decay coefficients at the excitation wavelength, and 3) sensitivity of the emission source term. Simplifying linearity assumptions are computationally attractive in that they cause the first and second terms to drop out of the formulation. The relative importance of the three terms is thus explored in order to determine the extent to which these approximations introduce error. Computational experiments show that, while the third term of the sensitivity matrix has the largest magnitude, the second term becomes increasingly significant as target fluorophore concentration or volume increases. Image reconstructions from experimental data confirm that neglecting the second term results in overestimation of sensitivities and consequently overestimation of the value and volume of the fluorescent target, whereas contributions of the first term are so low that they are probably not worth the additional computational costs.

Mesh:

Year:  2003        PMID: 14552576     DOI: 10.1109/TMI.2003.818165

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  4 in total

1.  A time domain fluorescence tomography system for small animal imaging.

Authors:  Anand T N Kumar; Scott B Raymond; Andrew K Dunn; Brian J Bacskai; David A Boas
Journal:  IEEE Trans Med Imaging       Date:  2008-08       Impact factor: 10.048

2.  Parameterized level-set based pharmacokinetic fluorescence optical tomography using the regularized Gauss-Newton filter.

Authors:  Omprakash Gottam; Naren Naik; Sanjay Gambhir
Journal:  J Biomed Opt       Date:  2018-10       Impact factor: 3.170

Review 3.  Pre-clinical whole-body fluorescence imaging: Review of instruments, methods and applications.

Authors:  Frederic Leblond; Scott C Davis; Pablo A Valdés; Brian W Pogue
Journal:  J Photochem Photobiol B       Date:  2009-11-26       Impact factor: 6.252

4.  A wavelet-based multiresolution reconstruction method for fluorescent molecular tomography.

Authors:  Wei Zou; Jiajun Wang; Kongpei Wu; David Dagan Feng
Journal:  Int J Biomed Imaging       Date:  2009-07-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.