Literature DB >> 14550866

A validated assay for measuring doxorubicin in biological fluids and tissues in an isolated lung perfusion model: matrix effect and heparin interference strongly influence doxorubicin measurements.

A Kümmerle1, T Krueger, M Dusmet, C Vallet, Y Pan, H B Ris, Laurent A Decosterd.   

Abstract

Doxorubicin is an antineoplasic agent active against sarcoma pulmonary metastasis, but its clinical use is hampered by its myelotoxicity and its cumulative cardiotoxicity, when administered systemically. This limitation may be circumvented using the isolated lung perfusion (ILP) approach, wherein a therapeutic agent is infused locoregionally after vascular isolation of the lung. The influence of the mode of infusion (anterograde (AG): through the pulmonary artery (PA); retrograde (RG): through the pulmonary vein (PV)) on doxorubicin pharmacokinetics and lung distribution was unknown. Therefore, a simple, rapid and sensitive high-performance liquid chromatography method has been developed to quantify doxorubicin in four different biological matrices (infusion effluent, serum, tissues with low or high levels of doxorubicin). The related compound daunorubicin was used as internal standard (I.S.). Following a single-step protein precipitation of 500 microl samples with 250 microl acetone and 50 microl zinc sulfate 70% aqueous solution, the obtained supernatant was evaporated to dryness at 60 degrees C for exactly 45 min under a stream of nitrogen and the solid residue was solubilized in 200 microl of purified water. A 100 microl-volume was subjected to HPLC analysis onto a Nucleosil 100-5 microm C18 AB column equipped with a guard column (Nucleosil 100-5 microm C(6)H(5) (phenyl) end-capped) using a gradient elution of acetonitrile and 1-heptanesulfonic acid 0.2% pH 4: 15/85 at 0 min-->50/50 at 20 min-->100/0 at 22 min-->15/85 at 24 min-->15/85 at 26 min, delivered at 1 ml/min. The analytes were detected by fluorescence detection with excitation and emission wavelength set at 480 and 550 nm, respectively. The calibration curves were linear over the range of 2-1000 ng/ml for effluent and plasma matrices, and 0.1 microg/g-750 microg/g for tissues matrices. The method is precise with inter-day and intra-day relative standard deviation within 0.5 and 6.7% and accurate with inter-day and intra-day deviations between -5.4 and +7.7%. The in vitro stability in all matrices and in processed samples has been studied at -80 degrees C for 1 month, and at 4 degrees C for 48 h, respectively. During initial studies, heparin used as anticoagulant was found to profoundly influence the measurements of doxorubicin in effluents collected from animals under ILP. Moreover, the strong matrix effect observed with tissues samples indicate that it is mandatory to prepare doxorubicin calibration standard samples in biological matrices which would reflect at best the composition of samples to be analyzed. This method was successfully applied in animal studies for the analysis of effluent, serum and tissue samples collected from pigs and rats undergoing ILP.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14550866     DOI: 10.1016/s0731-7085(03)00300-5

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  6 in total

1.  Adsorption of doxorubicin on poly(methyl methacrylate)-chitosan-heparin-coated activated carbon beads.

Authors:  Jianjun Miao; Fuming Zhang; Majde Takieddin; Shaker Mousa; Robert J Linhardt
Journal:  Langmuir       Date:  2012-02-22       Impact factor: 3.882

2.  Effect of fractionation on treatment outcome in local dual-frequency sonication and Dox-encapsulated nanomicelles.

Authors:  Hadi Hasanzadeh; Manijhe Mokhtari-Dizaji; S Zahra Bathaie; Zuhair M Hassan
Journal:  J Med Ultrason (2001)       Date:  2013-03-30       Impact factor: 1.314

3.  Dual-frequency ultrasound activation of nanomicellar doxorubicin in targeted tumor chemotherapy.

Authors:  Hadi Hasanzadeh; Manijhe Mokhtari-Dizaji; S Zahra Bathaie; Zuhair M Hassan; Amir Ali Shahbazfar
Journal:  J Med Ultrason (2001)       Date:  2013-10-05       Impact factor: 1.314

4.  A Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats.

Authors:  Marjan Daeihamed; Azadeh Haeri; Simin Dadashzadeh
Journal:  Iran J Pharm Res       Date:  2015       Impact factor: 1.696

5.  Solid phase microextraction chemical biopsy tool for monitoring of doxorubicin residue during in vivo lung chemo-perfusion.

Authors:  Barbara Bojko; Nikita Looby; Mariola Olkowicz; Anna Roszkowska; Bogumiła Kupcewicz; Pedro Reck Dos Santos; Khaled Ramadan; Shaf Keshavjee; Thomas K Waddell; German Gómez-Ríos; Marcos Tascon; Krzysztof Goryński; Marcelo Cypel; Janusz Pawliszyn
Journal:  J Pharm Anal       Date:  2020-09-02

6.  Application of Optical Methods for Determination of Concentration of Doxorubicin in Blood and Plasma.

Authors:  Tomasz Sikora; Karolina Morawska; Wiesław Lisowski; Paweł Rytel; Agnieszka Dylong
Journal:  Pharmaceuticals (Basel)       Date:  2022-01-18
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.