Literature DB >> 1454322

Comparison of photocoagulation with the argon, krypton, and diode laser indirect ophthalmoscopes in rabbit eyes.

J D Benner1, M Huang, L S Morse, L M Hjelmeland, M B Landers.   

Abstract

PURPOSE: The purpose of this study is to compare photocoagulation with the argon green, krypton red, and diode infrared laser indirect ophthalmoscopes in an experimental setting.
METHODS: Photocoagulation was performed with each of the laser indirect ophthalmoscopes in a grid pattern within one sector of the same eye of 14 Dutch-belted rabbits. Treatment was performed either with or without scleral depression. Measurements of the retinal burn diameters were performed after hemisecting the globes, and the burns were examined with light microscopy.
RESULTS: Variation in burn intensity and diameter (10% to 28%) was common with all 3 laser indirect ophthalmoscopes. Five times more output energy was required to make equivalent burns with the diode laser indirect ophthalmoscope than with the argon or krypton laser indirect ophthalmoscopes. Choriovitreal hemorrhages only occurred during scleral depression. Histopathologically, the argon green laser indirect ophthalmoscope burns spared the choroid and inner sclera, while the intense krypton and diode burns had full-thickness choroidal involvement and even thermal injury to the inner sclera. Scleral depression reduced the mean energy required to create equivalent burns with all three laser indirect ophthalmoscopes. There was a 10% to 40% reduction in the mean retinal burn diameter with scleral depression (argon green, P < 0.0005; krypton red, P < 0.0005; and diode, P < 0.025).
CONCLUSION: Photocoagulation with the argon green, krypton red, or diode infrared laser indirect ophthalmoscopes is a safe and effective method of retinal ablation. Decreasing the posterior nodal distance of the eye with scleral depression will produce a smaller spot on the retina with the laser indirect ophthalmoscope.

Entities:  

Mesh:

Year:  1992        PMID: 1454322     DOI: 10.1016/s0161-6420(92)31767-1

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  7 in total

1.  Cryotherapy and laser treatment for acute retinopathy of prematurity: refractive outcomes, a longitudinal study.

Authors:  F Laws; D Laws; D Clark
Journal:  Br J Ophthalmol       Date:  1997-01       Impact factor: 4.638

2.  Diagnostic ophthalmology.

Authors:  J Wolfer; B Grahn
Journal:  Can Vet J       Date:  1996-10       Impact factor: 1.008

3.  A comparative study of the effects of argon and diode laser photocoagulation on retinal oxygenation.

Authors:  H Funatsu; C A Wilson; B A Berkowitz; P L Sonkin
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1997-03       Impact factor: 3.117

4.  Diode laser for retinopathy of prematurity--early outcome.

Authors:  M Goggin; M O'Keefe
Journal:  Br J Ophthalmol       Date:  1993-09       Impact factor: 4.638

5.  Endophotocoagulation through perfluorodecalin in rabbit eyes.

Authors:  C Azzolini; R Brancato; G Trabucchi; F Camesasca; M Codenotti; M Verdi
Journal:  Int Ophthalmol       Date:  1994       Impact factor: 2.031

6.  Incidence of cataract development by 6 months' corrected age in the Early Treatment for Retinopathy of Prematurity study.

Authors:  Bradley V Davitt; Stephen P Christiansen; Robert J Hardy; Betty Tung; William V Good
Journal:  J AAPOS       Date:  2013-01-23       Impact factor: 1.220

7.  Refractive outcome following diode laser versus cryotherapy for eyes with retinopathy of prematurity.

Authors:  K Algawi; M Goggin; M O'Keefe
Journal:  Br J Ophthalmol       Date:  1994-08       Impact factor: 4.638

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.