Literature DB >> 1454305

Reliability of the tear break-up time technique of assessing tear stability and the locations of the tear break-up in Hong Kong Chinese.

P Cho1, B Brown, I Chan, R Conway, M Yap.   

Abstract

The measurement of tear break-up time (TBUT) in assessing stability of the tear film is somewhat controversial, even though the technique is widely used. We examined reliability of the technique within and among examiners and conclude that measurements of TBUT can be made reliably; full-beam observation of the cornea is preferable to scanning the cornea with a narrow slit in making the measurements. There may be differences in TBUT measurements made in the same subjects among examiners, but these differences are smaller with more experienced practitioners. In the Hong Kong Chinese (HK-Chinese), tear break-up appears to be more likely to first occur in the inferior periphery of the cornea. In this population mean TBUT is about 7.20 s; assuming a Gaussian distribution of TBUT values, 2.1 s should be adopted as the lower limit for normal TBUT in HK-Chinese.

Entities:  

Mesh:

Year:  1992        PMID: 1454305     DOI: 10.1097/00006324-199211000-00007

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  11 in total

Review 1.  Eye complaints in the office environment: precorneal tear film integrity influenced by eye blinking efficiency.

Authors:  P Wolkoff; J K Nøjgaard; P Troiano; B Piccoli
Journal:  Occup Environ Med       Date:  2005-01       Impact factor: 4.402

2.  Agreement between Automated and Traditional Measures of Tear Film Breakup.

Authors:  Stephanie M Cox; Kelly K Nichols; Jason J Nichols
Journal:  Optom Vis Sci       Date:  2015-09       Impact factor: 1.973

Review 3.  TFOS DEWS II Tear Film Report.

Authors:  Mark D P Willcox; Pablo Argüeso; Georgi A Georgiev; Juha M Holopainen; Gordon W Laurie; Tom J Millar; Eric B Papas; Jannick P Rolland; Tannin A Schmidt; Ulrike Stahl; Tatiana Suarez; Lakshman N Subbaraman; Omür Ö Uçakhan; Lyndon Jones
Journal:  Ocul Surf       Date:  2017-07-20       Impact factor: 5.033

4.  Mathematical modelling of glob-driven tear film breakup.

Authors:  L Zhong; C F Ketelaar; R J Braun; C G Begley; P E King-Smith
Journal:  Math Med Biol       Date:  2019-03-14       Impact factor: 1.854

Review 5.  Mechanisms, imaging and structure of tear film breakup.

Authors:  P Ewen King-Smith; Carolyn G Begley; Richard J Braun
Journal:  Ocul Surf       Date:  2017-09-20       Impact factor: 5.033

6.  Spatial Distribution of Noninvasive Break Up Times and Clinical Relevance in Healthy Participants and Mild Dry Eye.

Authors:  Louis Tong; Calesta Hui Yi Teo; Ryan Khee Jin Lee
Journal:  Transl Vis Sci Technol       Date:  2019-10-17       Impact factor: 3.283

7.  Angiogenin for the Diagnosis and Grading of Dry Eye Syndrome.

Authors:  Won Soo Kim; Sung Wook Wee; Seung Hoon Lee; Jae Chan Kim
Journal:  Korean J Ophthalmol       Date:  2016-05-18

8.  Keratograph 5M As A Useful And Objective Tool For Evaluating The Ocular Surface In Limbal Stem Cell Deficiency.

Authors:  Asunción Alfaro-Juárez; Manuel Caro-Magdaleno; Jesús Montero-Iruzubieta; Ana Fernández-Palacín; Ana Muñoz-Morales; Manuel Alberto Castilla-Martino; Consuelo Spínola-Muñoz; Enrique Rodríguez de la Rúa
Journal:  Clin Ophthalmol       Date:  2019-10-16

Review 9.  A Review of Imaging Biomarkers of the Ocular Surface.

Authors:  William W Binotti; Betul Bayraktutar; M Cuneyt Ozmen; Stephanie M Cox; Pedram Hamrah
Journal:  Eye Contact Lens       Date:  2020-03       Impact factor: 3.152

10.  Agreement of noninvasive tear break-up time measurement between Tomey RT-7000 Auto Refractor-Keratometer and Oculus Keratograph 5M.

Authors:  Ryan Lee; Sharon Yeo; Han Tun Aung; Louis Tong
Journal:  Clin Ophthalmol       Date:  2016-09-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.