Literature DB >> 14530420

An ex vivo assessment of a bonding technique using a self-etching primer.

C J Larmour1, D R Stirrups.   

Abstract

OBJECTIVE: This study assessed a new self-etch/priming system for use in orthodontic bonding.
SETTING: An ex vivo study.
METHOD: Three groups of 20 extracted premolar teeth were bonded with metal orthodontic brackets. Group 1 was bonded with Transbond using the conventional technique (control). Group 2 was bonded using the new Transbond-Plus combined etch/primer system to wet enamel and Group 3 to dry enamel. The teeth were debonded using an Instron Universal Testing Machine. The mean debond force was calculated for each group and compared statistically. The teeth were examined under the stereomicroscope to assess the site of debond and adhesive remnant index.
RESULTS: Group 2 (etch/primer on wet enamel) had the lowest mean debond value at 5.2 MPa. ANOVA and Tukey tests confirmed that the bond strength results of Group 2 were significantly lower than Groups 1 (P < 0.01) and 3 (P < 0.05). The enamel/resin interface was the commonest site of bond failure for both etch/primer groups (Groups 2 and 3). They had less retained resin and significantly (P < 0.001) lower ARI scores compared with Group 1 (control).
CONCLUSIONS: The results of this ex vivo study suggest that the self-etch primer should achieve adequate bond strengths when applied to dry enamel surfaces. In addition there should be less retained resin requiring removal at debond.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14530420     DOI: 10.1093/ortho/30.3.225

Source DB:  PubMed          Journal:  J Orthod        ISSN: 1465-3125


  4 in total

1.  Shear bond strength of orthodontic brackets bonded with a new self-adhering flowable resin composite.

Authors:  Cecilia Goracci; Mariam Margvelashvili; Agostino Giovannetti; Alessandro Vichi; Marco Ferrari
Journal:  Clin Oral Investig       Date:  2012-04-27       Impact factor: 3.573

2.  Effects of procedures of remineralization around orthodontics bracket bonded by self-etching primer on its shear bond strength.

Authors:  Mahmoud Al-Suleiman; Nick Silikas; David Watts
Journal:  J Orthod Sci       Date:  2012-07

3.  Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study.

Authors:  Behnam Mirzakouchaki; Sajjad Shirazi; Reza Sharghi; Samaneh Shirazi; Mahsan Moghimi; Shirin Shahrbaf
Journal:  J Clin Exp Dent       Date:  2016-02-01

4.  Comparative evaluation and influence of new Optibond eXTRa self-etch Universal adhesive and conventional Transbond XT on shear bond strength of orthodontic brackets-An in vitro study.

Authors:  Bhogi Siddarth; Kaladhar Reddy Aileni; Madhukar Reddy Rachala; Arun Kumar Dasari; Jaya Priyanka Mallepally; Pooja Reddy Thadisina; Shaik Navab
Journal:  J Orthod Sci       Date:  2022-08-24
  4 in total