Monte Carlo study of TLD measurements in air cavities.

Pia Haraldsson1, Tommy Knöös, Håkan Nyström, Per Engström.   

Abstract

Thermoluminescent dosimeters (TLDs) are used for verification of the delivered dose during IMRT treatment of head and neck carcinomas. The TLDs are put into a plastic tube, which is placed in the nasal cavities through the treated volume. In this study, the dose distribution to a phantom having a cylindrical air cavity containing a tube was calculated by Monte Carlo methods and the results were compared with data from a treatment planning system (TPS) to evaluate the accuracy of the TLD measurements. The phantom was defined in the DOSXYZnrc Monte Carlo code and calculations were performed with 6 MV fields, with the TLD tube placed at different positions within the cylindrical air cavity. A similar phantom was defined in the pencil beam based TPS. Differences between the Monte Carlo and the TPS calculations of the absorbed dose to the TLD tube were found to be small for an open symmetrical field. For a half-beam field through the air cavity, there was a larger discrepancy. Furthermore, dose profiles through the cylindrical air cavity show, as expected, that the treatment planning system overestimates the absorbed dose in the air cavity. This study shows that when using an open symmetrical field, Monte Carlo calculations of absorbed doses to a TLD tube in a cylindrical air cavity give results comparable to a pencil beam based treatment planning system.

Entities:  

Mesh:

Year:  2003        PMID: 14529213     DOI: 10.1088/0031-9155/48/18/401

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

Review 1.  Pattern of care and impact of prognostic factors on the outcome of head and neck extramedullary plasmacytoma: a systematic review and individual patient data analysis of 315 cases.

Authors:  Bhanuprasad Venkatesulu; Supriya Mallick; Prashanth Giridhar; Ashish Dutt Upadhyay; Goura K Rath
Journal:  Eur Arch Otorhinolaryngol       Date:  2017-12-09       Impact factor: 2.503

2.  Accuracy Evaluation of Collapsed Cone Convolution Superposition Algorithms for the Nasopharynx Interface in the Early Stage of Nasopharyngeal Carcinoma.

Authors:  Yuan-Chun Lai; Li-Chung Hung; Chien-Chung Jeng; Chen-Ju Feng; Tung-Hao Chang; Shih-Ming Hsu
Journal:  Biomed Res Int       Date:  2022-05-28       Impact factor: 3.246

3.  Dosimetry of interface region near closed air cavities for Co-60, 6 MV and 15 MV photon beams using Monte Carlo simulations.

Authors:  Chandra P Joshi; Johnson Darko; P B Vidyasagar; L John Schreiner
Journal:  J Med Phys       Date:  2010-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.