IMRT delivery verification using a spiral phantom.

Susan L Richardson1, Wolfgang A Tomé, Nigel P Orton, Todd R McNutt, Bhudatt R Paliwal.   

Abstract

In this paper we report on the testing and verification of a system for IMRT delivery quality assurance that uses a cylindrical solid water phantom with a spiral trajectory for radiographic film placement. This spiral film technique provides more complete dosimetric verification of the entire IMRT treatment than perpendicular film methods, since it samples a three-dimensional dose subspace rather than using measurements at only one or two depths. As an example, the complete analysis of the predicted and measured spiral films is described for an intracranial IMRT treatment case. The results of this analysis are compared to those of a single field perpendicular film technique that is typically used for IMRT QA. The comparison demonstrates that both methods result in a dosimetric error within a clinical tolerance of 5%, however the spiral phantom QA technique provides a more complete dosimetric verification while being less time consuming. To independently verify the dosimetry obtained with the spiral film, the same IMRT treatment was delivered to a similar phantom in which LiF thermoluminescent dosimeters were arranged along the spiral trajectory. The maximum difference between the predicted and measured TLD data for the 1.8 Gy fraction was 0.06 Gy for a TLD located in a high dose gradient region. This further validates the ability of the spiral phantom QA process to accurately verify delivery of an IMRT plan.

Entities:  

Mesh:

Year:  2003        PMID: 14528978     DOI: 10.1118/1.1603965

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

Review 1.  Intensity-modulated radiation therapy: emerging cancer treatment technology.

Authors:  T S Hong; M A Ritter; W A Tomé; P M Harari
Journal:  Br J Cancer       Date:  2005-05-23       Impact factor: 7.640

2.  3D VMAT Verification Based on Monte Carlo Log File Simulation with Experimental Feedback from Film Dosimetry.

Authors:  A R Barbeiro; A Ureba; J A Baeza; R Linares; M Perucha; E Jiménez-Ortega; S Velázquez; J C Mateos; A Leal
Journal:  PLoS One       Date:  2016-11-21       Impact factor: 3.240

3.  Evaluation of a new VMAT QA device, or the "X" and "O" array geometries.

Authors:  Vladimir Feygelman; Geoffrey Zhang; Craig Stevens; Benjamin E Nelms
Journal:  J Appl Clin Med Phys       Date:  2011-01-31       Impact factor: 2.102

4.  Advances in radiation therapy dosimetry.

Authors:  Bhudatt Paliwal; Dinesh Tewatia
Journal:  J Med Phys       Date:  2009-07

5.  Absolute dose verification of static intensity modulated radiation therapy (IMRT) with ion chambers of various volumes and TLD detectors.

Authors:  Hediye Acun-Bucht; Ebru Tuncay; Emin Darendeliler; Gönül Kemikler
Journal:  Rep Pract Oncol Radiother       Date:  2018-05-19

6.  Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom.

Authors:  Masao Tanooka; Hiroshi Doi; Hideharu Miura; Hiroyuki Inoue; Yasue Niwa; Yasuhiro Takada; Masayuki Fujiwara; Toshiyuki Sakai; Kiyoshi Sakamoto; Norihiko Kamikonya; Shozo Hirota
Journal:  J Radiat Res       Date:  2013-05-17       Impact factor: 2.724

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.