Literature DB >> 14528963

Quantitative imaging of bromine-76 and yttrium-86 with PET: a method for the removal of spurious activity introduced by cascade gamma rays.

Bradley J Beattie1, Ronald D Finn, Douglas J Rowland, Keith S Pentlow.   

Abstract

Positron Emission Tomography of bromine-76 and yttrium-86 results in the detection of coincident events that are not strictly associated with annihilation photon pairs. Instead, these coincidences occur because prompt gamma rays emitted by these nuclides result in cascades of photons that are emitted within the timing window of the PET scanner. Pairs of detected photons from these cascades are not angularly correlated and therefore contain little information regarding the location of their source. Furthermore, these coincidences are not removed by correction procedures (e.g., randoms, scatter) routinely applied to PET data. If left uncorrected, the cascade coincidences will result in spurious apparent activity within the PET images. A correction, applied within projection space, that removes the cascade coincidence signal from septa-in (i.e., two-dimensional) datasets is proposed and tested on phantom data.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14528963     DOI: 10.1118/1.1595599

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  24 in total

1.  Feasibility of 90Y TOF PET-based dosimetry in liver metastasis therapy using SIR-Spheres.

Authors:  Renaud Lhommel; Larry van Elmbt; Pierre Goffette; Marc Van den Eynde; François Jamar; Stanislas Pauwels; Stephan Walrand
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-04-27       Impact factor: 9.236

2.  ARRONAX, a high-energy and high-intensity cyclotron for nuclear medicine.

Authors:  Ferid Haddad; Ludovic Ferrer; Arnaud Guertin; Thomas Carlier; Nathalie Michel; Jacques Barbet; Jean-François Chatal
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-05-09       Impact factor: 9.236

Review 3.  Dosimetry of yttrium-labelled radiopharmaceuticals for internal therapy: 86Y or 90Y imaging?

Authors:  Stephan Walrand; Glenn D Flux; Mark W Konijnenberg; Roelf Valkema; Eric P Krenning; Renaud Lhommel; Stanislas Pauwels; Francois Jamar
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-03-11       Impact factor: 9.236

Review 4.  Accuracy and precision of radioactivity quantification in nuclear medicine images.

Authors:  Eric C Frey; John L Humm; Michael Ljungberg
Journal:  Semin Nucl Med       Date:  2012-05       Impact factor: 4.446

Review 5.  Quantitative imaging of 124I and 86Y with PET.

Authors:  Mark Lubberink; Hans Herzog
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-04-12       Impact factor: 9.236

6.  Correction technique for cascade gammas in I-124 imaging on a fully-3D, Time-of-Flight PET Scanner.

Authors:  Suleman Surti; Ryan Scheuermann; Joel S Karp
Journal:  IEEE Trans Nucl Sci       Date:  2009-06       Impact factor: 1.679

7.  Prompt-gamma compensation in Rb-82 myocardial perfusion 3D PET/CT.

Authors:  Fabio P Esteves; Jonathan A Nye; Akbar Khan; Russell D Folks; Raghuveer K Halkar; Ernest V Garcia; David M Schuster; Stamatios Lerakis; Paolo Raggi; John R Votaw
Journal:  J Nucl Cardiol       Date:  2009-11-24       Impact factor: 5.952

8.  Theranostic pretargeted radioimmunotherapy of colorectal cancer xenografts in mice using picomolar affinity ⁸⁶Y- or ¹⁷⁷Lu-DOTA-Bn binding scFv C825/GPA33 IgG bispecific immunoconjugates.

Authors:  Sarah M Cheal; Hong Xu; Hong-Fen Guo; Sang-Gyu Lee; Blesida Punzalan; Sandhya Chalasani; Edward K Fung; Achim Jungbluth; Pat B Zanzonico; Jorge A Carrasquillo; Joseph O'Donoghue; Peter M Smith-Jones; K Dane Wittrup; Nai-Kong V Cheung; Steven M Larson
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-11-24       Impact factor: 9.236

9.  Iodine-124 PET dosimetry in differentiated thyroid cancer: recovery coefficient in 2D and 3D modes for PET(/CT) systems.

Authors:  Walter Jentzen; Reiner Weise; Jürgen Kupferschläger; Lutz Freudenberg; Wolfgang Brandau; Ronald Bares; Wolfgang Burchert; Andreas Bockisch
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-10-10       Impact factor: 9.236

10.  Synthesis and in vitro and in vivo evaluation of 18F-labeled positron emission tomography (PET) ligands for imaging the vesicular acetylcholine transporter.

Authors:  Zhude Tu; Simon M N Efange; Jinbin Xu; Shihong Li; Lynne A Jones; Stanley M Parsons; Robert H Mach
Journal:  J Med Chem       Date:  2009-03-12       Impact factor: 7.446

View more