Literature DB >> 14528459

Composite surgical sutures with bioactive glass coating.

Aldo R Boccaccini1, Artemis G Stamboulis, Azrina Rashid, Judith A Roether.   

Abstract

A processing method was developed to coat polyglactin 910 (Vicryl) sutures with bioactive glass powder (45S5 Bioglass). High reproducibility and homogeneity of the coating in terms of microstructure and thickness along the suture length were achieved. Bioglass-coated sutures exhibited a high level of chemical reactivity in simulated body fluid (SBF), indicating their bioactive behavior. This was evident by the prompt formation of hydroxyapatite (HA) crystals on the surface after only 7 days of immersion in SBF. These crystals grew to form a thick HA layer (15 microm thickness) after 3 weeks in SBF. The tensile strength of the sutures was tested before and after immersion in SBF in order to assess the effect of the bioactive glass coating on suture degradation. The tensile strength of composite sutures was lower than that of as-received Vicryl sutures, 385 and 467 MPa, respectively. However, after 28 days of immersion in SBF the residual tensile strengths of coated and uncoated sutures were similar (83 and 88 MPa, respectively), indicating no negative effect of the HA layer formation on the suture strength. The effect of bioactive glass coating on the polymer degradation is discussed. The developed bioactive sutures represent interesting materials for applications in wound healing, fabrication of fibrous three-dimensional scaffolds for tissue engineering, and reinforcement elements for calcium-phosphate temporary implants. Copyright 2003 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14528459     DOI: 10.1002/jbm.b.10047

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  5 in total

1.  Bioactivity of degradable polymer sutures coated with bioactive glass.

Authors:  Oana Bretcanu; Enrica Verné; Luisa Borello; Aldo R Boccaccini
Journal:  J Mater Sci Mater Med       Date:  2004-08       Impact factor: 3.896

2.  [Cell transplantation for a CSF-fistula. Experience with fibrin glue and fibroblasts].

Authors:  G Wolf; P K Plinkert; B Schick
Journal:  HNO       Date:  2005-05       Impact factor: 1.284

3.  Vaterite deposition on biodegradable polymer foam scaffolds for inducing bone-like hydroxycarbonate apatite coatings.

Authors:  H Maeda; V Maquet; T Kasuga; Q Z Chen; J A Roether; A R Boccaccini
Journal:  J Mater Sci Mater Med       Date:  2007-06-12       Impact factor: 3.896

Review 4.  Update on Suture Techniques in Corneal Transplantation: A Systematic Review.

Authors:  Luca Pagano; Haider Shah; Omar Al Ibrahim; Kunal A Gadhvi; Giulia Coco; Jason W Lee; Stephen B Kaye; Hannah J Levis; Kevin J Hamill; Francesco Semeraro; Vito Romano
Journal:  J Clin Med       Date:  2022-02-18       Impact factor: 4.241

5.  Development and Characterization of Bioactive Glass Containing Composite Coatings with Ion Releasing Function for Antibiotic-Free Antibacterial Surgical Sutures.

Authors:  Francesca E Ciraldo; Kristin Schnepf; Wolfgang H Goldmann; Aldo R Boccaccini
Journal:  Materials (Basel)       Date:  2019-01-30       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.