Literature DB >> 14528379

Upper arm polytetrafluoroethylene grafts for dialysis access. Analysis of two different graft sizes: 6 mm and 6-8 mm.

Rosario García-Pajares1, José R Polo, Angel Flores, Enrique Gonzalez-Tabares, Juan V Solís.   

Abstract

The purpose of this retrospective study was to analyze 2 sizes of expanded polytetrafluoroethylene (PTFE) upper arm grafts for dialysis: 8 millimeters, tapered to 6 mm at the arterial side, and 6 millimeters. All upper arm PTFE grafts (Gore-Tex(R)) were performed between January 1981 and April 1997. Patient characteristics, complication rate, and patency rates were compared for both kind of grafts. Five hundred and seven PTFE grafts were analyzed (183 6-mm grafts and 324 6- to 8-mm grafts). Early failure was found in 5 grafts (2.7%) in 6-mm grafts, and in 5 grafts (1.5%) in 8-mm grafts (not significant). Steal syndrome was found in 1 patient (0.5%) of the 6-mm group, and in 11 (3.4%) of the 8-mm grafts (p=0.085). The rate of late complications requiring surgical repair was 0.56 episode per graft-year in the 6-mm grafts group, and 0.33 in the 8-mm grafts (p<0.001). Primary patency rates of 6-mm grafts were 72%, 33%, and 19% at 1, 3, and 5 years; and secondary patency rates were 86%, 68%, 56%, and 44% at 1, 3, 5, and 6 years, respectively. In the 8-mm grafts group, primary patency rates were 77%, 52%, and 39% at 1, 3, and 5 years; and secondary patency rates were 92%, 84%, 73%, and 66% at 1, 3, 5, and 6 years, respectively. Comparison of patency rates of 6-mm and 8-mm grafts were statistically significant (p<0.001) for both primary and secondary curves. However, secondary survival curves were similar for both kind of grafts in a subpopulation of diabetic patients. The authors conclude that the 8-mm graft, tapered to 6 mm at the arterial side, is a dialysis graft with fewer complications and a better patency rate than grafts of 6 mm placed in the same anatomical position, at least in a population of nondiabetic patients. Steal syndrome was observed in some cases of diabetic and older patients with a large-bore graft. Thus, this kind of prosthesis should be avoided in this population. On the other hand, this is not a prospective, randomized study made with any intention for comparison. Therefore, the aforementioned conclusions must be cautiously considered.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14528379     DOI: 10.1177/153857440303700505

Source DB:  PubMed          Journal:  Vasc Endovascular Surg        ISSN: 1538-5744            Impact factor:   1.089


  7 in total

1.  Evaluation of the hemodynamics in straight 6-mm and tapered 6- to 8-mm grafts as upper arm hemodialysis vascular access.

Authors:  M Sarmast; H Niroomand-Oscuii; F Ghalichi; E Samiei
Journal:  Med Biol Eng Comput       Date:  2014-08-12       Impact factor: 2.602

Review 2.  Outcome of GORE® ACUSEAL graft for brachial-axillary vascular access in chronic haemodialysis patients: Cohort retrospective single-centre study.

Authors:  Tamer Sayed; Mahmoud Montasser; Yasser Ashoor; Ahmed Saad
Journal:  Ann Med Surg (Lond)       Date:  2020-11-17

Review 3.  Neointimal hyperplasia associated with synthetic hemodialysis grafts.

Authors:  Li Li; Christi M Terry; Yan-Ting E Shiu; Alfred K Cheung
Journal:  Kidney Int       Date:  2008-07-30       Impact factor: 10.612

4.  Outcomes of two different polytetrafluoroethylene graft sizes in patients undergoing maintenance hemodialysis.

Authors:  R Afshar; S Sanavi; S Afshin-Majd; A Davati
Journal:  Indian J Nephrol       Date:  2009-10

5.  Patency rate and complications of polytetrafluoroethylene grafts compared with polyurethane grafts for hemodialysis access.

Authors:  Hassan Ravari; Gholam Hossein Kazemzade; Mohammad Hadi Saied Modaghegh; Patricia Khashayar
Journal:  Ups J Med Sci       Date:  2010-03-11       Impact factor: 2.384

6.  Prosthetic Hemodialysis Access-induced Distal Hand Ischemia and its Contributors in Diabetics.

Authors:  S M Alamshah; I Nazari; A Nahidi; M Sametzadeh; S Khodabakhshi
Journal:  Indian J Nephrol       Date:  2017 May-Jun

7.  Upper extremity axillary loop grafts: an opportunity in hemodialysis access.

Authors:  Jalaladin Khoshnevis; Mohammad Reza Sobhiyeh; Saran Lotfolahzadah; Fatemah Hoseinzadegan Shirazi; Amir Hosein Jalali
Journal:  Nephrourol Mon       Date:  2012-12-15
  7 in total