Literature DB >> 1452169

Adaptive filter for event-related bioelectric signals using an impulse correlated reference input: comparison with signal averaging techniques.

P Laguna1, R Jané, O Meste, P W Poon, P Caminal, H Rix, N V Thakor.   

Abstract

Many bioelectric signals result from the electrical response of physiological systems to an impulse that can be internal (ECG signals) or external (evoked potentials). In this paper an adaptive impulse correlated filter (AICF) for event-related signals that are time-locked to a stimulus is presented. This filter estimates the deterministic component of the signal and removes the noise uncorrelated with the stimulus, even if this noise is colored, as in the case of evoked potentials. The filter needs two inputs: the signal (primary input) and an impulse correlated with the deterministic component (reference input). We use the LMS algorithm to adjust the weights in the adaptive process. First, we show that the AICF is equivalent to exponentially weighted averaging (EWA) when using the LMS algorithm. A quantitative analysis of the signal-to-noise ratio improvement, convergence, and misadjustment error is presented. A comparison of the AICF with ensemble averaging (EA) and moving window averaging (MWA) techniques is also presented. The adaptive filter is applied to real high-resolution ECG signals and time-varying somatosensory evoked potentials.

Mesh:

Year:  1992        PMID: 1452169     DOI: 10.1109/10.161335

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  17 in total

1.  Analysis of the ST-T complex of the electrocardiogram using the Karhunen--Loève transform: adaptive monitoring and alternans detection.

Authors:  P Laguna; G B Moody; J García; A L Goldberger; R G Mark
Journal:  Med Biol Eng Comput       Date:  1999-03       Impact factor: 2.602

2.  A tracing evoked potential estimator.

Authors:  K S Fung; F H Chan; F K Lam; P W Poon
Journal:  Med Biol Eng Comput       Date:  1999-03       Impact factor: 2.602

3.  Evoked potential estimation using modified time-sequenced adaptive filter.

Authors:  F H Chan; W Qiu; F K Lam; P W Poon; M K Lam
Journal:  Med Biol Eng Comput       Date:  1998-07       Impact factor: 2.602

4.  Real-time ocular artifact suppression using recurrent neural network for electro-encephalogram based brain-computer interface.

Authors:  A Erfanian; B Mahmoudi
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

5.  Adaptive estimation of QRS complex wave features of ECG signal by the Hermite model.

Authors:  P Laguna; R Jane; S Olmos; N V Thakor; H Rix; P Caminal
Journal:  Med Biol Eng Comput       Date:  1996-01       Impact factor: 2.602

6.  Estimation of habituation and signal-to-noise ratio of cortical evoked potentials to oesophageal electrical and mechanical stimulation.

Authors:  M V Kamath; G Tougas; S Hollerbach; R Premji; D Fitzpatrick; G Shine; A R Upton
Journal:  Med Biol Eng Comput       Date:  1997-07       Impact factor: 2.602

7.  Detection of brainstem auditory evoked potential by adaptive filtering.

Authors:  F H Chan; F K Lam; P W Poon; W Qiu
Journal:  Med Biol Eng Comput       Date:  1995-01       Impact factor: 2.602

8.  Event synchronous adaptive filter based atrial activity estimation in single-lead atrial fibrillation electrocardiograms.

Authors:  Jeon Lee; Mi-hye Song; Dong-gu Shin; Kyoung-joung Lee
Journal:  Med Biol Eng Comput       Date:  2012-06-21       Impact factor: 2.602

9.  Adaptive filters for analysis of intra-cardiac signals.

Authors:  N V Thakor
Journal:  Med Biol Eng Comput       Date:  1994-07       Impact factor: 2.602

10.  Rapid measurement of somatosensory evoked potential response to cerebral artery occlusion.

Authors:  P Poon; R C Koehler; N V Thakor
Journal:  Med Biol Eng Comput       Date:  1995-05       Impact factor: 2.602

View more