Literature DB >> 14520150

Staging of functional damage in glaucoma using frequency doubling technology.

Paolo Brusini1, Claudia Tosoni.   

Abstract

PURPOSE: To evaluate three new approaches for staging severity of glaucomatous visual field defects using frequency doubling technology. PATIENTS AND METHODS: One hundred and four patients with either ocular hypertension or chronic glaucoma were tested with both standard automated perimetry (SAP, 30-2 Humphrey threshold test) and frequency doubling technology (N-30 threshold test). Standard automated perimetry results were classified into four groups (normal tests, early defects, moderate defects, and severe defects) using the Glaucoma Staging System. Frequency doubling technology tests were also classified in four groups using three different approaches: frequency doubling technology probability map analysis, considering the number and location of disturbed points, frequency doubling technology MD and PSD indices, graphed on a two-axis diagram (FDT Staging System), and an abnormality score, based on both the statistical significance and the spatial location of depressed points. A control group of 20 eyes from 20 normal subjects was also tested and classified in the same way. The Cohen Kappa was used to compare the level of agreement between the three frequency doubling technology methods of classification and the glaucoma staging system.
RESULTS: Measure of agreement was 0.679 using probability map assessment, 0.793 using the frequency doubling technology staging system, and 0.663 using the abnormality score. The specificity rate was 95% for all three methods.
CONCLUSIONS: All the studied approaches were able to correctly stage the glaucomatous functional damage, but the frequency doubling technology staging system was the easiest and quickest method. Moreover, it is the only method that supplies information on the characteristics of the defect, without requiring any other time-consuming procedures.

Entities:  

Mesh:

Year:  2003        PMID: 14520150     DOI: 10.1097/00061198-200310000-00004

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  7 in total

1.  The distribution of visual field defects per quadrant in standard automated perimetry as compared to frequency doubling technology perimetry.

Authors:  Wadih M Zein; Ziad F Bashshur; Rola F Jaafar; Baha' N Noureddin
Journal:  Int Ophthalmol       Date:  2010-10-06       Impact factor: 2.031

2.  [Flicker and conventional perimetry in comparison with structural changes in glaucoma].

Authors:  F Dannheim
Journal:  Ophthalmologe       Date:  2013-02       Impact factor: 1.059

3.  Prevalence and predictors of depression among participants with glaucoma in a nationally representative population sample.

Authors:  Sophia Y Wang; Kuldev Singh; Shan C Lin
Journal:  Am J Ophthalmol       Date:  2012-07-11       Impact factor: 5.258

4.  Association between visual field defects and quality of life in the United States.

Authors:  Mary Qiu; Sophia Y Wang; Kuldev Singh; Shan C Lin
Journal:  Ophthalmology       Date:  2013-12-15       Impact factor: 12.079

5.  Mitochondrial damage in the trabecular meshwork occurs only in primary open-angle glaucoma and in pseudoexfoliative glaucoma.

Authors:  Alberto Izzotti; Mariagrazia Longobardi; Cristina Cartiglia; Sergio Claudio Saccà
Journal:  PLoS One       Date:  2011-01-20       Impact factor: 3.240

6.  Mental Health Status and Quality of Life in Undiagnosed Glaucoma Patients: A Nationwide Population-Based Study.

Authors:  Kyoung In Jung; Chan Kee Park
Journal:  Medicine (Baltimore)       Date:  2016-05       Impact factor: 1.889

7.  Assessment of Risk Factors for Advanced Open Angle Glaucoma Presentation among Patients Visiting Jimma University Medical Center, Jimma, Ethiopia.

Authors:  Kumale Tolesa Daba; Girum W/Gebreal Gessesse; Jemmal Mohammed Molla; Tsedeke Asaminew Alemu
Journal:  Ethiop J Health Sci       Date:  2022-09
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.