Literature DB >> 14518793

Design, development, and characteristics of an in-shoe triaxial pressure measurement transducer utilizing a single element of piezoelectric copolymer film.

Mohammad A Razian1, Matthew G Pepper.   

Abstract

In gait analysis, there is growing awareness of the need to simultaneously measure shear and vertical forces for the diagnosis and treatment assessment of pathological foot disorders. This is especially the case in the measurement of the forces between the plantar surface of the foot and the shoe. Although clinical awareness of the need to simultaneously measure shear and vertical forces under the foot has increased little has been done to provide the technology. This is mainly due to the difficulty in constructing devices capable of carrying out this task in the in-shoe environment. The aim of this paper is to describe the development and characteristics of a miniature triaxial transducer measuring 10 x 10 x 2.7 mm and a weight of only 2 g. This transducer is capable of simultaneously measuring three orthogonal forces under any location of the plantar surface of the foot utilizing a single element piezoelectric copolymer P(VDF-TrFE). Transducer sensitivity, linearity, hysteresis, cross-talk and temperature dependence is presented. As well as in-shoe force measurement, this triaxial transducer could have other biomedical and general engineering applications, e.g., prosthetic interface forces, handgrip forces, sport, robotics, etc.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14518793     DOI: 10.1109/tnsre.2003.818185

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  10 in total

1.  BioKin: an ambulatory platform for gait kinematic and feature assessment.

Authors:  Samitha W Ekanayake; Andrew J Morris; Mike Forrester; Pubudu N Pathirana
Journal:  Healthc Technol Lett       Date:  2015-02-25

2.  American Society of Biomechanics Clinical Biomechanics Award 2012: plantar shear stress distributions in diabetic patients with and without neuropathy.

Authors:  Metin Yavuz
Journal:  Clin Biomech (Bristol, Avon)       Date:  2013-11-15       Impact factor: 2.063

3.  Measuring Plantar Tissue Stress in People With Diabetic Peripheral Neuropathy: A Critical Concept in Diabetic Foot Management.

Authors:  Peter A Lazzarini; Ryan T Crews; Jaap J van Netten; Sicco A Bus; Malindu E Fernando; Paul J Chadwick; Bijan Najafi
Journal:  J Diabetes Sci Technol       Date:  2019-04-29

Review 4.  Electroactive polymers for sensing.

Authors:  Tiesheng Wang; Meisam Farajollahi; Yeon Sik Choi; I-Ting Lin; Jean E Marshall; Noel M Thompson; Sohini Kar-Narayan; John D W Madden; Stoyan K Smoukov
Journal:  Interface Focus       Date:  2016-08-06       Impact factor: 3.906

5.  Investigation of Regression Methods for Reduction of Errors Caused by Bending of FSR-Based Pressure Sensing Systems Used for Prosthetic Applications.

Authors:  Chakaveh Ahmadizadeh; Carlo Menon
Journal:  Sensors (Basel)       Date:  2019-12-13       Impact factor: 3.576

6.  Abnormal Gait Detection Using Wearable Hall-Effect Sensors.

Authors:  Courtney Chheng; Denise Wilson
Journal:  Sensors (Basel)       Date:  2021-02-09       Impact factor: 3.576

Review 7.  Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahmad Adikan
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

8.  Gait Shear and Plantar Pressure Monitoring: A Non-Invasive OFS Based Solution for e-Health Architectures.

Authors:  Cátia Tavares; M Fátima Domingues; Anselmo Frizera-Neto; Tiago Leite; Cátia Leitão; Nélia Alberto; Carlos Marques; Ayman Radwan; Eduardo Rocon; Paulo André; Paulo Antunes
Journal:  Sensors (Basel)       Date:  2018-04-25       Impact factor: 3.576

Review 9.  Measurement of Walking Ground Reactions in Real-Life Environments: A Systematic Review of Techniques and Technologies.

Authors:  Erfan Shahabpoor; Aleksandar Pavic
Journal:  Sensors (Basel)       Date:  2017-09-12       Impact factor: 3.576

Review 10.  Indirect Measurement of Ground Reaction Forces and Moments by Means of Wearable Inertial Sensors: A Systematic Review.

Authors:  Andrea Ancillao; Salvatore Tedesco; John Barton; Brendan O'Flynn
Journal:  Sensors (Basel)       Date:  2018-08-05       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.