The longitudinal Young's modulus of cortical bone in the midshaft of human femur and its correlation with CT scanning data.

M Cuppone1, B B Seedhom, E Berry, A E Ostell.   

Abstract

This study was concerned with establishing the regional variations in the magnitude of the longitudinal Young's modulus of the cortical bone in the femoral midshaft and with investigating whether a relationship existed between the Young's modulus of bone and the CT number. Were such a relationship to exist this would provide a noninvasive method of assessing the quality of bone in the regions of fixation of implants to bone. The data would be of considerable aid to designers of implant stems to withstand the stresses arising at its interface with the bone. Five pairs of fresh frozen human femora were used. Several beam-shaped small specimens were methodically harvested from each pair and were used to measure the longitudinal modulus adopting the three-point bending test, which was carried out with a specially constructed and validated apparatus. CT scans of the bone were obtained, prior to harvesting the specimens, and the CT number was measured at locations corresponding with the specimen sites. The results indicate that in the femoral midshaft the cortical bone has an average Young's modulus value of 18600 +/- 1900 MPa. This agrees well with data obtained by other researchers using different experimental methods. Statistical analyses revealed no regional variations in the value of the longitudinal modulus of the bone. No correlation was found between the bone modulus and the CT number. Thus a noninvasive method for establishing the bone properties still remains a challenge.

Entities:  

Mesh:

Year:  2003        PMID: 14517712     DOI: 10.1007/s00223-002-2123-1

Source DB:  PubMed          Journal:  Calcif Tissue Int        ISSN: 0171-967X            Impact factor:   4.333


  13 in total

1.  Radially and axially graded multizonal bone graft substitutes targeting critical-sized bone defects from polycaprolactone/hydroxyapatite/tricalcium phosphate.

Authors:  Asli Ergun; Xiaojun Yu; Antonio Valdevit; Arthur Ritter; Dilhan M Kalyon
Journal:  Tissue Eng Part A       Date:  2012-09-14       Impact factor: 3.845

2.  Matrix rigidity induces osteolytic gene expression of metastatic breast cancer cells.

Authors:  Nazanin S Ruppender; Alyssa R Merkel; T John Martin; Gregory R Mundy; Julie A Sterling; Scott A Guelcher
Journal:  PLoS One       Date:  2010-11-15       Impact factor: 3.240

3.  A comparative study of orthotropic and isotropic bone adaptation in the femur.

Authors:  Diogo M Geraldes; Andrew T M Phillips
Journal:  Int J Numer Method Biomed Eng       Date:  2014-04-21       Impact factor: 2.747

4.  A preclinical numerical assessment of a polyetheretherketone femoral component in total knee arthroplasty during gait.

Authors:  Lennert de Ruiter; Dennis Janssen; Adam Briscoe; Nico Verdonschot
Journal:  J Exp Orthop       Date:  2017-02-01

Review 5.  Antimicrobial and Osseointegration Properties of Nanostructured Titanium Orthopaedic Implants.

Authors:  Marcus Jäger; Herbert P Jennissen; Florian Dittrich; Alfons Fischer; Hedda Luise Köhling
Journal:  Materials (Basel)       Date:  2017-11-13       Impact factor: 3.623

6.  First Results of a New Vacuum Plasma Sprayed (VPS) Titanium-Coated Carbon/PEEK Composite Cage for Lumbar Interbody Fusion.

Authors:  Sven Hoppe; Christoph E Albers; Tarek Elfiky; Moritz C Deml; Helena Milavec; Sebastian F Bigdon; Lorin M Benneker
Journal:  J Funct Biomater       Date:  2018-03-14

7.  Consideration of multiple load cases is critical in modelling orthotropic bone adaptation in the femur.

Authors:  Diogo M Geraldes; Luca Modenese; Andrew T M Phillips
Journal:  Biomech Model Mechanobiol       Date:  2015-11-17

Review 8.  New Ti-Alloys and Surface Modifications to Improve the Mechanical Properties and the Biological Response to Orthopedic and Dental Implants: A Review.

Authors:  Yvoni Kirmanidou; Margarita Sidira; Maria-Eleni Drosou; Vincent Bennani; Athina Bakopoulou; Alexander Tsouknidas; Nikolaos Michailidis; Konstantinos Michalakis
Journal:  Biomed Res Int       Date:  2016-01-14       Impact factor: 3.411

9.  The mechanical response of a polyetheretherketone femoral knee implant under a deep squatting loading condition.

Authors:  Lennert de Ruiter; Dennis Janssen; Adam Briscoe; Nico Verdonschot
Journal:  Proc Inst Mech Eng H       Date:  2017-11-04       Impact factor: 1.617

10.  Ceramics with the signature of wood: a mechanical insight.

Authors:  D Bigoni; R Cavuoto; D Misseroni; M Paggi; A Ruffini; S Sprio; A Tampieri
Journal:  Mater Today Bio       Date:  2019-10-24
View more