Literature DB >> 14512009

Endovascular treatment of the descending thoracic aorta.

D Lambrechts1, F Casselman, P Schroeyers, R De Geest, P D'Haenens, I Degrieck.   

Abstract

OBJECTIVES: to report our initial experience with endovascular stent graft repair of a variety of thoracic aortic pathology.
DESIGN: retrospective single center study.
MATERIAL AND METHODS: between February 2000 and January 2002, endovascular stent graft repair was performed in 26 patients: traumatic aortic isthmus rupture (n=3), Type B dissection (n=11) and descending thoracic aortic aneurysm (n=12). The deployed stent graft systems were AneuRx-Medtronic (n=1), Talent-Medtronic (n=13) and Excluder-Gore (n=12).
RESULTS: successful deployment of the stent grafts in the intended position was achieved in all patients. No hospital mortality neither paraplegia were observed. Late, non procedure related, death occurred in four patients (15%). Access artery complications with rupture of the iliac artery occurred in two patients and were managed by iliac-femoral bypass. The left subclavian artery was overstented in seven patients (27%). Only the first patient received a carotido-subclavian bypass. The mean maximal aortic diameter decreased significantly in patients treated for descending thoracic aneurysm. Only one patient had an endoleak type II after 6 months without enlargement of the aneurysm. Complete thrombosis of the thoracic false lumen occurred in all but one patient treated for Type B dissection 6 months postoperatively. Two patients underwent a consecutive stent graft placement, due to a large re-entry tear distal to the first stent graft.
CONCLUSIONS: endovascular stent graft repair for Type B dissection, descending thoracic aneurysm and aortic isthmus rupture is a promising less-invasive alternative to surgical repair. Further studies are mandatory to determine its long-term efficacy.

Entities:  

Mesh:

Year:  2003        PMID: 14512009     DOI: 10.1016/s1078-5884(03)00150-3

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  5 in total

Review 1.  [Multidetector computed tomography in the diagnosis of non-traumatic vascular emergencies].

Authors:  B Baumert; M Körner; M Sadeghi-Azandaryani; C Rummeny; M Reiser; U Linsenmaier
Journal:  Radiologe       Date:  2009-06       Impact factor: 0.635

2.  Endovascular repair of a ruptured descending thoracic aortic aneurysm.

Authors:  Michael DeFrain; Neil E Strickman; Branimir J Ljubic; Kathryn G Dougherty; Igor D Gregoric
Journal:  Tex Heart Inst J       Date:  2006

3.  Endovascular repair in management of thoracic aortic aneurysms.

Authors:  Hakan Bingol; Hikmet Iyem; Hakki Tankut Akay; Bahri Ustunsoz; Cengiz Bolcal; Sahin Ugurer; Gokce Sirin; Ufuk Demirkilic; Harun Tatar
Journal:  Int J Cardiovasc Imaging       Date:  2006-06-29       Impact factor: 2.357

4.  Preprocedural planning for endovascular stent-graft placement.

Authors:  Gregory Kicska; Harold Litt
Journal:  Semin Intervent Radiol       Date:  2009-03       Impact factor: 1.513

5.  Hybrid treatment of isolated aortic arch aneurysms.

Authors:  D Laganà; G Carrafiello; D Lumia; A Ianniello; F Fontana; M Mangini; P Castelli; C Fugazzola
Journal:  Radiol Med       Date:  2009-09-22       Impact factor: 3.469

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.