Literature DB >> 14509953

The use of the multislice CT for the determination of respiratory lung tumor movement in stereotactic single-dose irradiation.

Holger Hof1, Klaus K Herfarth, Marc Münter, Marco Essig, Michael Wannenmacher, Jürgen Debus.   

Abstract

BACKGROUND: In three-dimensional (3-D) precision high-dose radiation therapy of lung tumors, the exact definition of the planning target volume (PTV) is indispensable. Therefore, the feasibility of a 3-D determination of respiratory lung tumor movements by the use of a multislice CT scanner was investigated. PATIENTS AND METHODS: The respiratory motion of 21 lung tumors in 20 consecutively treated patients was examined. An abdominal pressure device for the reduction of respiratory movement was used in 14 patients. Two regions of the tumor were each scanned repeatedly at the same table position, showing four simultaneously acquired slices for each cycle. Stereotactic coordinates were determined for one anatomic reference point in each tumor region (Figure 1). The 3-D differences of these coordinates between the sequentially obtained cycles were assessed (Figure 2), and a correlation with the tumor localization was performed.
RESULTS: In the craniocaudal (Z-) direction the mean tumor movement was 5.1 mm (standard deviation [SD] 2.4 mm, maximum 10 mm), in the ventrodorsal (Y-) direction 3.1 mm (SD 1.5 mm, maximum 6.7 mm), and in the lateral (X-) direction 2.6 mm (SD 1.4 mm, maximum 5.8 mm; Figures 3 to 5). Inter- and intraindividual differences were present in each direction. With an abdominal pressure device no clinically significant difference between tumors in different location was seen.
CONCLUSION: The 3-D assessment of lung tumor movements due to breathing is possible by the use of multislice CT. The determination, indispensable to the PTV definition, should be performed individually for several regions, because of the inter- and intraindividual deviations detected.

Entities:  

Mesh:

Year:  2003        PMID: 14509953     DOI: 10.1007/s00066-003-1070-8

Source DB:  PubMed          Journal:  Strahlenther Onkol        ISSN: 0179-7158            Impact factor:   3.621


  15 in total

1.  Clinical utility of co-registered respiratory-gated( 99m)Tc-Technegas/MAA SPECT-CT images in the assessment of regional lung functional impairment in patients with lung cancer.

Authors:  Kazuyoshi Suga; Yasuhiko Kawakami; Mohammed Zaki; Tomio Yamashita; Kensaku Shimizu; Naofumi Matsunaga
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-06-10       Impact factor: 9.236

Review 2.  [Visualization of pulmonary nodules with magnetic resonance imaging (MRI)].

Authors:  C Plathow; H-P Meinzer; H-U Kauczor
Journal:  Radiologe       Date:  2006-04       Impact factor: 0.635

Review 3.  [Radiation therapy of lung carcinoma].

Authors:  S Oertel; J Debus; H Hof; M Bischof
Journal:  Radiologe       Date:  2010-08       Impact factor: 0.635

4.  Radiobiological analysis of stereotactic body radiation therapy for an evidence-based planning target volume of the lung using multiphase CT images obtained with a pneumatic abdominal compression apparatus: a case study.

Authors:  Arun Chairmadurai; Harish Chandra Goel; Sandeep Kumar Jain; Pawan Kumar
Journal:  Radiol Phys Technol       Date:  2017-11-11

5.  Estimation of pulmonary motion in healthy subjects and patients with intrathoracic tumors using 3D-dynamic MRI: initial results.

Authors:  Christian Plathow; Max Schoebinger; Felix Herth; Siegfried Tuengerthal; Heinz-Peter Meinzer; Hans-Ulrich Kauczor
Journal:  Korean J Radiol       Date:  2009 Nov-Dec       Impact factor: 3.500

6.  Evaluation of image registration spatial accuracy using a Bayesian hierarchical model.

Authors:  Suyu Liu; Ying Yuan; Richard Castillo; Thomas Guerrero; Valen E Johnson
Journal:  Biometrics       Date:  2014-02-27       Impact factor: 2.571

Review 7.  [Stereotactic irradiation of lung tumors].

Authors:  H Hof; K Herfarth; J Debus
Journal:  Radiologe       Date:  2004-05       Impact factor: 0.635

Review 8.  [Computed tomography of the lungs. A step into the fourth dimension].

Authors:  J Dinkel; C Hintze; N Rochet; C Thieke; J Biederer
Journal:  Radiologe       Date:  2009-08       Impact factor: 0.635

9.  [CT-guided interstitial brachytherapy of lung malignancies. Technique and first results].

Authors:  J Ricke; P Wust; S Hengst; G Wieners; M Pech; H Herzog; R Felix
Journal:  Radiologe       Date:  2004-07       Impact factor: 0.635

10.  Measurement of diaphragmatic length during the breathing cycle by dynamic MRI: comparison between healthy adults and patients with an intrathoracic tumor.

Authors:  Christian Plathow; Christian Fink; Sebastian Ley; Michael Puderbach; Monica Eichinger; Astrid Schmähl; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2004-05-01       Impact factor: 5.315

View more