Literature DB >> 14509342

Solid-phase microextraction coupled with high-performance liquid chromatography for the determination of phenylurea herbicides in aqueous samples.

Hsin-Hang Lin1, Yu-Hsiang Sung, Shang-Da Huang.   

Abstract

Solid-phase microextraction coupled with high-performance liquid chromatography was successfully applied to the analysis of nine phenylurea herbicides (metoxuron, monuron, chlorotoluron, isoproturon, monolinuron, metobromuron, buturon, linuron, and chlorbromuron). Polydimethylsiloxane-divinylbenzene (PDMS-DVB, 60 microm) and Carbowax-templated resin (CW-TPR, 50 microm) fibers were selected from four commercial fibers for further study because of their better extraction efficiencies. The parameters of the desorption procedure were studied and optimized. The effects of the properties of analytes and fiber coatings, carryover, duration and temperature of absorption, pH, organic solvent and ionic strength of samples were also investigated. External calibration with an aqueous standard can be used for the analysis of environmental samples (lake water) using either PDMS-DVB or CW-TPR fibers. Good precisions (1.0-5.9%) are achieved for this method, and the detection limits are at the level of 0.5-5.1 ng/ml.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14509342     DOI: 10.1016/s0021-9673(03)01169-5

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  p-Phenylenediamine-modified graphene oxide as a sorbent for solid-phase extraction of phenylurea herbicides, nitroimidazoles, chlorophenols, phenylurea insecticides and phthalates.

Authors:  Liying Guo; Lin Hao; Tian Gao; Chun Wang; Qiuhua Wu; Zhi Wang
Journal:  Mikrochim Acta       Date:  2019-06-22       Impact factor: 5.833

2.  Application of the Doehlert design to optimize the signal obtained in photochemically induced fluorescence for the determination of eight phenylureas.

Authors:  M D Gil-García; M Martínez-Galera; P Parrilla-Vázquez; A R Mughari; I M Ortiz-Rodríguez
Journal:  J Fluoresc       Date:  2007-12-12       Impact factor: 2.217

3.  A magnetic covalent aromatic polymer as an efficient and recyclable adsorbent for phenylurea herbicides.

Authors:  Lin Hao; Yibo Wang; Chun Wang; Qiuhua Wu; Zhi Wang
Journal:  Mikrochim Acta       Date:  2019-06-11       Impact factor: 5.833

4.  Monoclonal Antibody-Based Immunosensor for the Electrochemical Detection of Chlortoluron Herbicide in Groundwaters.

Authors:  Anaïs Surribas; Lise Barthelmebs; Thierry Noguer
Journal:  Biosensors (Basel)       Date:  2021-12-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.