Do the Finapres and Colin radial artery tonometer measure the same blood pressure changes following deflation of thigh cuffs?

A A Birch1, S L Morris.   

Abstract

The objective of this work was to determine if systematic differences exist between blood pressure time series measured by two non-invasive techniques. Cerebral blood flow autoregulation is often measured while a change in blood pressure is induced by deflation of thigh cuffs. To interpret the result a continuous measurement of arterial blood pressure is required. The Finapres is a non-invasive blood pressure monitor that is often used when assessing autoregulation but there is uncertainty about its reliability. A more recent device, the Colin tonometer, uses radial artery tonometry, which may prove to be a more reliable non-invasive method of obtaining a blood pressure waveform. Twenty healthy volunteers were recruited; blood pressure trends following cuff deflation were measured simultaneously with a Finapres and a Colin tonometer. A significant difference was found between the blood pressure waveforms measured with the two devices. The most striking difference was a slower recovery time measured with the Finapres (Wilcoxon signed rank test P < 0.001). Peripheral vasoaction may be distorting the measurement of blood pressure by the Finapres. This would account for the difference that exists between the techniques. Comparison with a direct arterial line would confirm which non-invasive measurement is more accurate.

Mesh:

Year:  2003        PMID: 14509303     DOI: 10.1088/0967-3334/24/3/302

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  6 in total

Review 1.  A Review of Noninvasive Methodologies to Estimate the Blood Pressure Waveform.

Authors:  Tasbiraha Athaya; Sunwoong Choi
Journal:  Sensors (Basel)       Date:  2022-05-23       Impact factor: 3.847

2.  The cardiac output from blood pressure algorithms trial.

Authors:  James X Sun; Andrew T Reisner; Mohammed Saeed; Thomas Heldt; Roger G Mark
Journal:  Crit Care Med       Date:  2009-01       Impact factor: 7.598

3.  Tissue-informative mechanism for wearable non-invasive continuous blood pressure monitoring.

Authors:  Sung Hun Woo; Yun Young Choi; Dae Jung Kim; Franklin Bien; Jae Joon Kim
Journal:  Sci Rep       Date:  2014-10-21       Impact factor: 4.379

4.  Cerebral blood volume and oxygen supply uniformly increase following various intrathoracic pressure strains.

Authors:  Zhongxing Zhang; Nina Bolz; Marco Laures; Margit Oremek; Christoph Schmidt; Ming Qi; Ramin Khatami
Journal:  Sci Rep       Date:  2017-08-21       Impact factor: 4.379

5.  Quantitative analysis of sensor for pressure waveform measurement.

Authors:  Shing-Hong Liu; Chu-Chang Tyan
Journal:  Biomed Eng Online       Date:  2010-01-21       Impact factor: 2.819

Review 6.  Blood Pressure Sensors: Materials, Fabrication Methods, Performance Evaluations and Future Perspectives.

Authors:  Ahmed Al-Qatatsheh; Yosry Morsi; Ali Zavabeti; Ali Zolfagharian; Nisa Salim; Abbas Z Kouzani; Bobak Mosadegh; Saleh Gharaie
Journal:  Sensors (Basel)       Date:  2020-08-11       Impact factor: 3.576