Relative wear of enamel opposing low-fusing dental porcelain.

Nancy L Clelland1, Vaishali Agarwala, Lisa A Knobloch, Robert R Seghi.   

Abstract

PURPOSE: This study evaluated the wear of human enamel opposing 5 low-fusing dental porcelains and a traditional feldspathic control. In a second experiment, the repeatability of the test method and the effect of ceramic overfiring on enamel wear were also evaluated.
MATERIALS AND METHODS: Five low-fusing dental porcelains--Finesse (FI), Rhapsody (RP), IPS d.Sign (DS), Omega 900 (OM), and Duceram LFC (LFC)--and 1 traditional feldspathic porcelain--VMK 68 (VMK)--were formed into disks (n = 10) and used as substrate for the wear test. Enamel was harvested from extracted human molars and machined into cusps with a 5-mm spherical radius (n = 60). The Oregon Health Sciences University oral wear simulator was used to simulate chewing and the size of the resulting enamel wear facets (in mm(2)) were evaluated after a specified number of chewing cycles. A portion of the experiment was duplicated to assess the repeatability of the data and determine the effects of overfiring on enamel wear. Data were subjected to analysis of variance and post hoc tests to determine significant differences. After wear testing, scanning electron micrographs were made using representative ceramic samples from each group.
RESULTS: The results indicate that none of the low-fusing ceramics resulted in significantly less wear than the VMK control. In fact, 3 of the low-fusing porcelains (OM, RP, LFC) resulted in significantly greater enamel wear than VMK. Enamel wear was not significantly affected (p = 0.29) by the increased ceramic firing temperature. Wear data were repeatable, with no significant difference (p = 0.56) between the enamel wear from 2 separate experiments. The results from both experiments indicated that ceramic material significantly affected enamel wear (p <0.001). There was significantly less enamel wear opposite DS than LFC.
CONCLUSIONS: This work suggests that variations in ceramic composition and microstructure may affect the opposing enamel wear, but that low-fusing temperatures do not necessarily guarantee low enamel wear. Although the clinical relevance of this testing apparatus may be questioned, the testing method was repeatable.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14508738     DOI: 10.1016/S1059-941X(03)00051-2

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  6 in total

1.  A comparative evaluation of wear of enamel caused by ceramics with different fusion temperatures.

Authors:  Meenakshi Khandelwal; Deshraj Jain
Journal:  J Indian Prosthodont Soc       Date:  2012-11-01

2.  Three years in vivo wear: core-ceramic, veneers, and enamel antagonists.

Authors:  Josephine F Esquivel-Upshaw; William F Rose; Allyson A Barrett; Erica R Oliveira; Mark C K Yang; Arthur E Clark; Kenneth J Anusavice
Journal:  Dent Mater       Date:  2012-03-10       Impact factor: 5.304

Review 3.  Advancements in all-ceramics for dental restorations and their effect on the wear of opposing dentition.

Authors:  Haroon Rashid; Zeeshan Sheikh; Syed Misbahuddin; Murtaza Raza Kazmi; Sameer Qureshi; Muhammad Zuhaib Uddin
Journal:  Eur J Dent       Date:  2016 Oct-Dec

4.  Considerations for ceramic inlays in posterior teeth: a review.

Authors:  Christa D Hopp; Martin F Land
Journal:  Clin Cosmet Investig Dent       Date:  2013-04-18

5.  Effect of two different finishing systems on surface roughness of feldspathic and fluorapatite porcelains in ceramo-metal restorations: Comparative in vitro study.

Authors:  Cherry Anmol; Sumeet Soni
Journal:  J Int Soc Prev Community Dent       Date:  2014-01

6.  Novel methodology for measuring intraoral wear in enamel and dental restorative materials.

Authors:  Josephine F Esquivel-Upshaw; Shu-Min Hsu; Ana C Bohórquez; Nader Abdulhameed; Gary W Scheiffele; Mijin Kim; Dan Neal; John Chai; Fan Ren
Journal:  Clin Exp Dent Res       Date:  2020-09-21
  6 in total