Literature DB >> 14501736

11-year outcome analysis of endourethral prosthesis for the treatment of recurrent bulbar urethral stricture.

Darshan K Shah1, Elliot M Paul, Gopal H Badlani.   

Abstract

PURPOSE: In a North American multicenter trial of endourethral prosthesis for the treatment of recurrent bulbar urethral stricture we reported 2-year followup results for patients treated with the UroLume endoprosthesis (American Medical Systems, Inc., Minnetonka, Minnesota) between 1989 and 1996. From that same study we report long-term effectiveness and safety results on 24 of 179 patients, all of whom have completed 11 years of followup.
MATERIALS AND METHODS: The North American Study Group enrolled 179 patients with recurrent bulbar urethral stricture between March 1989 and April 1996. Eleven-year post-implantation followup was obtained for 24 of these original patients in a post-approval study. Evaluation included uroflowmetry before versus after insertion, urinary symptom score, local tissue changes and percentage of stent covered by epithelium.
RESULTS: At 11 years mean flow rates before and after stenting were 9.5 and 20.8 ml per second, respectively, and mean urinary symptom scores were 11.3 before and 3.04 after stent. No demonstrable tissue changes were visualized at the site of the stent in 31.8%, while 40.9% had mild, 22.7% had moderate and 4.6% had marked changes. There were 8 patients who underwent 9 re-treatment procedures within the stented area during followup.
CONCLUSIONS: When used appropriately the UroLume Endoprosthesis is an effective treatment for recurrent bulbar urethral stricture. It has low morbidity, re-treatment and explantation rates, and local tissue change was mild or nonexistent in the majority of patients.

Entities:  

Mesh:

Year:  2003        PMID: 14501736     DOI: 10.1097/01.ju.0000087623.82024.f2

Source DB:  PubMed          Journal:  J Urol        ISSN: 0022-5347            Impact factor:   7.450


  5 in total

1.  [Possibilities for surgical correction of an anastomotic stricture after radical prostatectomy].

Authors:  D Pfister; R Epplen; D Porres-Knoblauch; A Heidenreich
Journal:  Urologe A       Date:  2011-11       Impact factor: 0.639

2.  [S2e guideline of the German urologists: Instrumental treatment of benign prostatic hyperplasia].

Authors:  T Bschleipfer; T Bach; R Berges; K Dreikorn; C Gratzke; S Madersbacher; M-S Michel; R Muschter; M Oelke; O Reich; C Tschuschke; K Höfner
Journal:  Urologe A       Date:  2016-02       Impact factor: 0.639

Review 3.  Recent advances in the field of urology.

Authors:  Chester J Koh; Anthony Atala
Journal:  Curr Urol Rep       Date:  2006-01       Impact factor: 3.092

4.  Impacted calculus within a urethral stent: A rare cause of urinary retention.

Authors:  Shanmugasundaram Rajaian; Ganesh Gopalakrishnan; Santosh Kumar; Nitin S Kekre
Journal:  Indian J Urol       Date:  2011-01

5.  Comparison of Diagnostic Value of Sonourethrography with Retrograde Urethrography in Diagnosis of Anterior Urethral Stricture.

Authors:  Reza Shahsavari; Seyed Morteza Bagheri; Hamed Iraji
Journal:  Open Access Maced J Med Sci       Date:  2017-06-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.