RATIONALE AND OBJECTIVES: To investigate the potential of a novel manganese-based magnetic resonance (MR) contrast agent, EVP 1001-1 for the evaluation of myocardial ischemia. METHODS: MR imaging with EVP 1001-1 was performed on 6 Yorkshire pigs, and T1 relaxation times were calculated. One animal served as a control, 2 were subjected to an acute coronary artery occlusion and 3 provided a model of chronic ischemia. RESULTS: Administration of the agent in the control and acute coronary occlusion model demonstrated a short plasma half-life (approximately 1.5 minutes) and rapid myocardial uptake in nonoccluded regions, with long retention times in the myocardium (>1 hour) and no evidence of redistribution. In the chronic ischemia model, differential enhancement was observed between normal and ischemic tissue, particularly under dobutamine-induced stress. CONCLUSIONS: These properties suggest the use of EVP 1001-1 for steady-state imaging of myocardial perfusion. Contrast administration could be performed under stress conditions outside the scanner, with high-resolution MR images reflecting the stress condition acquired after the stress has subsided.
RATIONALE AND OBJECTIVES: To investigate the potential of a novel manganese-based magnetic resonance (MR) contrast agent, EVP 1001-1 for the evaluation of myocardial ischemia. METHODS: MR imaging with EVP 1001-1 was performed on 6 Yorkshire pigs, and T1 relaxation times were calculated. One animal served as a control, 2 were subjected to an acute coronary artery occlusion and 3 provided a model of chronic ischemia. RESULTS: Administration of the agent in the control and acute coronary occlusion model demonstrated a short plasma half-life (approximately 1.5 minutes) and rapid myocardial uptake in nonoccluded regions, with long retention times in the myocardium (>1 hour) and no evidence of redistribution. In the chronic ischemia model, differential enhancement was observed between normal and ischemic tissue, particularly under dobutamine-induced stress. CONCLUSIONS: These properties suggest the use of EVP 1001-1 for steady-state imaging of myocardial perfusion. Contrast administration could be performed under stress conditions outside the scanner, with high-resolution MR images reflecting the stress condition acquired after the stress has subsided.
Authors: Rajesh Dash; Jaehoon Chung; Fumiaki Ikeno; Annett Hahn-Windgassen; Yuka Matsuura; Mihoko V Bennett; Jennifer K Lyons; Tomohiko Teramoto; Robert C Robbins; Michael V McConnell; Alan C Yeung; Todd J Brinton; Phillip P Harnish; Phillip C Yang Journal: Circ Cardiovasc Imaging Date: 2011-06-30 Impact factor: 7.792
Authors: Eric M Gale; Hsiao-Ying Wey; Ian Ramsay; Yi-Fen Yen; David E Sosnovik; Peter Caravan Journal: Radiology Date: 2017-11-08 Impact factor: 11.105
Authors: Juliano L Fernandes; Pippa Storey; Jose Alvaro da Silva; Gabriel S de Figueiredo; Jose M Kalaf; Otavio R Coelho Journal: J Cardiovasc Magn Reson Date: 2011-01-14 Impact factor: 5.364
Authors: Iris Yuwen Zhou; Ian A Ramsay; Ilknur Ay; Pamela Pantazopoulos; Nicholas J Rotile; Alison Wong; Peter Caravan; Eric M Gale Journal: Invest Radiol Date: 2021-04-01 Impact factor: 10.065
Authors: Rajesh Dash; Paul J Kim; Yuka Matsuura; Fumiaki Ikeno; Scott Metzler; Ngan F Huang; Jennifer K Lyons; Patricia K Nguyen; Xiaohu Ge; Cheryl Wong Po Foo; Michael V McConnell; Joseph C Wu; Alan C Yeung; Phillip Harnish; Phillip C Yang Journal: J Am Heart Assoc Date: 2015-07-27 Impact factor: 5.501
Authors: Nick B Spath; Gerard Thompson; Andrew H Baker; Marc R Dweck; David E Newby; Scott I K Semple Journal: Heart Date: 2019-07-23 Impact factor: 5.994