Literature DB >> 1445131

Intrapartum fetal stimulation testing.

M Umstad1, C Bailey, M Permezel.   

Abstract

Intrapartum vibroacoustic stimulation testing (VAST) had a sensitivity of 100%, a specificity of 59.6% and a positive predictive value of 27.6% for the detection of fetal acidosis in this study of 60 cases. The use of VAST could significantly reduce the requirement for fetal capillary blood sampling. However, fetal scalp stimulation (FSS) was found to be an unreliable test to exclude fetal acidosis.

Entities:  

Mesh:

Year:  1992        PMID: 1445131     DOI: 10.1111/j.1479-828x.1992.tb01951.x

Source DB:  PubMed          Journal:  Aust N Z J Obstet Gynaecol        ISSN: 0004-8666            Impact factor:   2.100


  1 in total

1.  Fetal vibroacoustic stimulation in computerized cardiotocographic analysis: the role of short-term variability and approximate entropy.

Authors:  Maria Laura Annunziata; Mariamaddalena Scala; Natascia Giuliano; Salvatore Tagliaferri; Olga Carmela Maria Imperato; Francesca Giovanna Esposito; Marta Campanile; Andrea Di Lieto
Journal:  J Pregnancy       Date:  2012-01-16
  1 in total