Errors and artifacts of Doppler flowmeters and their solution.

K W Johnston, B C Maruzzo, R S Cobbold.   

Abstract

Continuous-wave Doppler ultrasound flowmeters are essential instruments for the vascular surgeon. Unfortunately, when used for quantitative purposes, they yield a flow velocity waveform that is substantially in error. Current directional continuous-wave Doppler velocimeters used a O-crossing detector to convert the Doppler signal to a waveform. Unfortunately, there are several inherent problems with this technique, and velocity waveforms are produced that have significant artifacts or errors. In this report, it is shown that a multifilter system is a simple, inexpensive alternative to systems using a O-crossing detector, and furthermore, permits real-time display of the Doppler waveform. The severity of the underlying arterial disease can be quantified by the calculation of pulsatility index. The pulsatility index was calculated from the Doppler waveforms recorded from peripheral arteries in 155 limbs and showed an excellent correlation with the severity of atherosclerosis as assessed by arteriography.

Entities:  

Mesh:

Year:  1977        PMID: 144466     DOI: 10.1001/archsurg.1977.01370110069007

Source DB:  PubMed          Journal:  Arch Surg        ISSN: 0004-0010


  6 in total

1.  Improved real-time spectrum analyser for Doppler-shift blood-velocity waveforms.

Authors:  B A Coghlan; M G Taylor
Journal:  Med Biol Eng Comput       Date:  1979-05       Impact factor: 2.602

2.  Vertebral artery Doppler sonography.

Authors:  R Winter; S Biedert; T Staudacher; H Betz; R Reuther
Journal:  Eur Arch Psychiatry Neurol Sci       Date:  1987

3.  Evaluation of cerebral blood flow changes by transfontanelle Doppler ultrasound in infantile hydrocephalus.

Authors:  C Alvisi; M Cerisoli; M Giulioni; P Monari; G P Salvioli; F Sandri; C Lippi; L Bovicelli; G Pilu
Journal:  Childs Nerv Syst       Date:  1985       Impact factor: 1.475

Review 4.  New technology in echocardiography I: Doppler techniques.

Authors:  W N McDicken; P R Hoskins; C M Moran; G R Sutherland
Journal:  Heart       Date:  1996-06       Impact factor: 5.994

5.  Continuous wave Doppler ultrasound in evaluation of cerebral blood flow in neonates.

Authors:  P H Gray; E A Griffin; J E Drumm; D E Fitzgerald; N M Duignan
Journal:  Arch Dis Child       Date:  1983-09       Impact factor: 3.791

6.  Non-invasive assessment of the steal phenomenon following femoro-femoral bypass.

Authors:  H Yamashita; K Hayakawa; M Akagi
Journal:  Jpn J Surg       Date:  1990-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.