Literature DB >> 144439

Dynamic compliance of arterial grafts.

R N Baird, I G Kidson, G J L'Italien, W M Abbott.   

Abstract

A cantilever transducer has been developed which allows measurements of diastolic diameter and diameter change in response to pulse pressure in dissected blood vessels during sterile procedures. Preliminary results indicate that it will detect subtle changes in wall elastic properties of arterial grafts at subtle changes in wall elastic properties of arterial grafts at and following implantation, which changes may influence graft function. Compliance, the percentage change in volume per unit pressure, was greater in normal canine femoral artery than in autogenous vein grafts (AVG). Two new graft materials were tested. Mesh-covered modified human umbilical cord vein (DBM) was similar in compliance to AVG but more compliant than double-velour Dacron. Diastolic diameter changes were also recorded. After 2 wk, all three graft materials had increased in diameter: AVG by 8%, DBM by 6%, and Dacron by 5%. After 3 mo, AVG diameter increased by 24%.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 144439     DOI: 10.1152/ajpheart.1977.233.5.H568

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  9 in total

Review 1.  Current understanding of intimal hyperplasia and effect of compliance in synthetic small diameter vascular grafts.

Authors:  YeJin Jeong; Yuan Yao; Evelyn K F Yim
Journal:  Biomater Sci       Date:  2020-07-09       Impact factor: 6.843

2.  The evolution of morphologic and biomechanical changes in reversed and in-situ vein grafts.

Authors:  R P Cambria; J Megerman; D C Brewster; D F Warnock; J Hasson; W M Abbott
Journal:  Ann Surg       Date:  1987-02       Impact factor: 12.969

3.  Assessment of algorithms used to compute the fast Fourier transform of left ventricular pressure on a microcomputer.

Authors:  A E Marble; J W Ashe; D H Tsang; D Belliveau; D N Swingler
Journal:  Med Biol Eng Comput       Date:  1985-03       Impact factor: 2.602

4.  Diagnosis and monitoring in arterial surgery: the use of ultrasound and related techniques.

Authors:  R N Baird
Journal:  Ann R Coll Surg Engl       Date:  1982-03       Impact factor: 1.891

5.  In vivo determination of human arterial compliance: preliminary investigation of a new technique.

Authors:  M E Hansen; E K Yucel; J Megerman; G J L'Italien; W M Abbott; A C Waltman
Journal:  Cardiovasc Intervent Radiol       Date:  1994 Jan-Feb       Impact factor: 2.740

6.  Characterization of human female breast and abdominal skin elasticity using a bulge test.

Authors:  Mazen Diab; Nishamathi Kumaraswamy; Gregory P Reece; Summer E Hanson; Michelle C Fingeret; Mia K Markey; Krishnaswamy Ravi-Chandar
Journal:  J Mech Behav Biomed Mater       Date:  2019-12-26

7.  Postoperative alterations in size of Dacron aortic grafts: an ultrasonic evaluation.

Authors:  D B Nunn; M H Freeman; P C Hudgins
Journal:  Ann Surg       Date:  1979-06       Impact factor: 12.969

8.  The effect of wall mechanical properties on patency of arterial grafts.

Authors:  I G Kidson
Journal:  Ann R Coll Surg Engl       Date:  1983-01       Impact factor: 1.891

Review 9.  Old Myths, New Concerns: the Long-Term Effects of Ascending Aorta Replacement with Dacron Grafts. Not All That Glitters Is Gold.

Authors:  Cristiano Spadaccio; Francesco Nappi; Nawwar Al-Attar; Fraser W Sutherland; Christophe Acar; Antonio Nenna; Marcella Trombetta; Massimo Chello; Alberto Rainer
Journal:  J Cardiovasc Transl Res       Date:  2016-05-31       Impact factor: 4.132

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.