| Literature DB >> 1444359 |
A B Chen1, A A Championsmith, J Blanchard, J Gorrell, B A Niepelt, M M Federici, J Formento, D V Sinicropi.
Abstract
A multiple antigen ELISA for E. coli proteins (ECPs) that may be present in purified recombinant human interferon-gamma (rIFN-gamma) was developed. SDS-PAGE and Western blotting analyses showed that the assay antibodies reacted with a wide spectrum of ECPs in the standard and with ECPs in a production run. In spike recovery studies, rIFN-gamma at concentrations of 0.05 mg/mL and higher augmented the immunoreactivity of the ECPs in the standard curve (1.3-40.0 ng ECPs/mL) by approx 50%. To determine ECP content in purified rIFN-gamma, 0.2 mg/mL of rIFN-gamma was added to the standard curve diluent to compensate for enhanced immunoreactivity. The assay was precise (interassay precision of ECP controls < or = 4.1 %CV) and accurate with recoveries of 111-115% of expected for ECPs (15-40 ng/mL) spiked into purified rIFN-gamma (1 mg/mL). Linearity of dilution for ECPs spiked into rIFN-gamma was obtained (r = 0.999). Moreover, linearity of dilution was obtained for ECPs in "in-process" samples, demonstrating the required condition of antibody excess for this type of multiple antigen ELISA. ECPs were not detectable in several purified lots of rIFN-gamma. Therefore, these lots contained < 1.3 ppm ECPs.Entities:
Mesh:
Substances:
Year: 1992 PMID: 1444359 DOI: 10.1007/bf02929693
Source DB: PubMed Journal: Appl Biochem Biotechnol ISSN: 0273-2289 Impact factor: 2.926