Literature DB >> 1443715

Time-course of respiratory depression after an alfentanil infusion-based anesthetic.

M E Goldberg1, M Torjman, R R Bartkowski, C T Mora, T Boerner, J L Seltzer.   

Abstract

Postoperative respiratory depression after alfentanil administration has been described in several case reports. The effects of a prolonged alfentanil infusion on the CO2 response curve or cognitive function have not been studied. Twenty-one ASA physical status I or II patients were studied after a prolonged alfentanil infusion (> 90 min) to determine the incidence of postoperative respiratory depression, arterial O2 desaturation, and impairment of cognitive function. Each patient's recovery was observed at 30-min intervals for evidence of respiratory depression (utilizing the Read CO2 rebreathing method), desaturation by pulse oximetry (severe desaturation defined as arterial O2 saturation < 90%), and cognitive function (utilizing Trieger dot and digit substitution tests). Plasma samples were also examined for secondary elevations in alfentanil plasma concentrations. Significant depression of the CO2 response curve and cognitive function was found up to 1 h postoperatively. Arterial O2 desaturation was seen in 11 of 21 patients (52%). No correlation was found between arterial O2 desaturation and cognitive function scores or CO2 rebreathing results. Increased depression of the CO2 response curve was not necessarily associated with severe desaturation episodes. A secondary increase in plasma alfentanil concentration was detected in 5 of the 21 patients (24%), but these patients did not experience further depression of the CO2 response curve. We conclude that prolonged alfentanil administration may result in severe arterial O2 desaturation with significant depression of the hypercapnic respiratory drive during the first hour in the postanesthesia care unit, even though the majority of our patients were easily aroused in response to verbal stimuli.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1443715     DOI: 10.1213/00000539-199212000-00015

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  4 in total

Review 1.  Recovery room problems or problems in the PACU.

Authors:  D K Rose
Journal:  Can J Anaesth       Date:  1996-05       Impact factor: 5.063

2.  Measurement of CO2 response with the breath-by-breath automatic acquisition of the breathing pattern and occlusion pressure.

Authors:  M Torjman; H Schieren; C T Mora; R R Bartkowski
Journal:  J Clin Monit       Date:  1995-05

3.  Sedative and ventilatory effects of midazolam infusion: effect of flumazenil reversal.

Authors:  C T Mora; M Torjman; P F White
Journal:  Can J Anaesth       Date:  1995-08       Impact factor: 5.063

4.  Effect of difelikefalin, a selective kappa opioid receptor agonist, on respiratory depression: A randomized, double-blind, placebo-controlled trial.

Authors:  Eugene R Viscusi; Marc C Torjman; Catherine L Munera; Joseph W Stauffer; Beatrice S Setnik; Sukirti N Bagal
Journal:  Clin Transl Sci       Date:  2021-07-21       Impact factor: 4.689

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.