Literature DB >> 1443213

Suction effusion fluid from skin and constituent analysis: new candidate for interstitial fluid.

S Kayashima1, T Arai, M Kikuchi, N Nagata, N Ito, T Kuriyama, J Kimura.   

Abstract

The authors analyzed the constituents of effuse transcutaneous fluid, labeled suction effusion fluid (SEF), and monitored its glucose concentration during glucose loading in rabbits (Japan White, female) under pentobarbital anesthesia. The SEF was sampled by suctioning corneal layer-stripped skin at 400 mmHg absolute pressure. The SEF proved to have nearly the same concentrations as serum for lower-molecular-weight substances such as glucose, creatinine, and urea nitrogens, but not for higher-molecular-weight substances such as serum proteins. The SEF protein concentration was one-fourth that of serum protein. Proteins > 100 kDa molecular mass were barely detectable in the SEF. Monitoring of SEF glucose change every 10 min during intravenous glucose loading was successfully accomplished, and SEF glucose concentration followed blood glucose concentration with a 10-min delay. The SEF was thought to consist of interstitial fluid and/or effuse fluid from small vessels in subcutaneous tissue.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1443213     DOI: 10.1152/ajpheart.1992.263.5.H1623

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  5 in total

1.  A percutaneous device to study glucose kinetics in subcutaneous tissue fluid.

Authors:  M Gerritsen; J A Lutterman; J A Jansen
Journal:  J Mater Sci Mater Med       Date:  2000-08       Impact factor: 3.896

2.  Microneedle Array Technique for the Longitudinal Extraction of Interstitial Fluid without Hair Removal.

Authors:  Robert M Taylor; Abdul-Mehdi S Ali; Yiliang Zhu; Alicia M Bolt; Justin T Baca
Journal:  Methods Protoc       Date:  2022-06-03

3.  Feasibility of Interstitial Fluid Ketone Monitoring with Microneedles.

Authors:  Robert M Taylor; Justin T Baca
Journal:  Metabolites       Date:  2022-05-10

4.  Human Suction Blister Fluid Composition Determined Using High-Resolution Metabolomics.

Authors:  Megan M Niedzwiecki; Pradnya Samant; Douglas I Walker; ViLinh Tran; Dean P Jones; Mark R Prausnitz; Gary W Miller
Journal:  Anal Chem       Date:  2018-02-27       Impact factor: 6.986

5.  Extraction and biomolecular analysis of dermal interstitial fluid collected with hollow microneedles.

Authors:  Philip R Miller; Robert M Taylor; Bao Quoc Tran; Gabrielle Boyd; Trevor Glaros; Victor H Chavez; Raga Krishnakumar; Anupama Sinha; Kunal Poorey; Kelly P Williams; Steven S Branda; Justin T Baca; Ronen Polsky
Journal:  Commun Biol       Date:  2018-10-22
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.