| Literature DB >> 14431155 |
Abstract
The construction of a modified Hartley oscillator transmitter activated through a pressure switch is described. When this device is placed within the rumen of a cow which is allowed unrestricted movement in the pasture, frequency-modulation signals are transmitted to a recording receiver whenever a preselected pressure is exceeded. The pressure at which transmission begins is determined by the capacitance across the coil of the circuit.Entities:
Keywords: STOMACH/physiology
Mesh:
Year: 1960 PMID: 14431155 DOI: 10.1126/science.131.3400.611
Source DB: PubMed Journal: Science ISSN: 0036-8075 Impact factor: 47.728