Literature DB >> 1442570

Comparison of thallium-201 and technetium-99m methoxyisobutyl isonitrile.

F J Wackers1.   

Abstract

Thallium-201 (201Tl) is a well-established radionuclide used in myocardial perfusion imaging for assessing the presence and prognostic significance of coronary artery disease. Recently, technetium-99m hexakis-2-methoxyisobutyl isonitrile (99mTc-sestamibi) has become available for the same diagnostic and prognostic procedures. This discussion compares the imaging characteristics and clinical applications of 201Tl with those of 99mTc-sestamibi. There is a strong diagnostic concordance between the 2 agents in symptomatic patients. Various comparative clinical trials have shown in numerous patients that both agents have a similar diagnostic yield in both planar and single-photon emission computed tomography (SPECT) imaging. Because of better image quality of the 99mTc agent, there is a trend toward better specificity and normalcy rate, in comparison to 201Tl. However, when using reinjection imaging protocols, 201Tl retains a unique place as an imaging agent to identify viable myocardium.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1442570     DOI: 10.1016/0002-9149(92)90036-x

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  7 in total

1.  The accuracy of 1-day dual-isotope myocardial SPECT in a population with high prevalence of coronary artery disease.

Authors:  Reginald G E J Groutars; J Fred Verzijlbergen; Monique M C Tiel-van Buul; Aeilco H Zwinderman; Carl A P L Ascoop; Norbert M van Hemel; Ernst E van der Wall
Journal:  Int J Cardiovasc Imaging       Date:  2003-06       Impact factor: 2.357

2.  Prognostic value and quality of life in patients with normal rest thallium-201/stress technetium 99m-tetrofosmin dual-isotope myocardial SPECT.

Authors:  R G Groutars; J F Verzijlbergen; A J Muller; C A Ascoop; M M Tiel-van Buul; A H Zwinderman; N M van Hemel; E E van der Wall
Journal:  J Nucl Cardiol       Date:  2000 Jul-Aug       Impact factor: 5.952

3.  Accuracy of exercise stress technetium 99m sestamibi SPECT imaging in the evaluation of the extent and location of coronary artery disease in patients with an earlier myocardial infarction.

Authors:  A Elhendy; F B Sozzi; R T van Domburg; J J Bax; M L Geleijnse; R Valkema; E P Krenning; J R Roelandt
Journal:  J Nucl Cardiol       Date:  2000 Sep-Oct       Impact factor: 5.952

Review 4.  A consideration of current clinical options for stress imaging in the diagnosis and evaluation of coronary artery disease.

Authors:  E H Botvinick
Journal:  J Nucl Cardiol       Date:  1994 Sep-Oct       Impact factor: 5.952

5.  A comparative evaluation of Tl-201 and Tc-99m sestamibi myocardial perfusion spect imaging in diabetic patients.

Authors:  Ozgür Omür; Zehra Ozcan; Murat Argon; Ebru Tani Acar
Journal:  Int J Cardiovasc Imaging       Date:  2007-06-19       Impact factor: 2.357

Review 6.  Evaluating coronary artery disease noninvasively--which test for whom?

Authors:  T M Chou; T M Amidon
Journal:  West J Med       Date:  1994-08

7.  Influence of patient height and weight and type of stress on myocardial count density during SPECT imaging with thallium-201 and technetium 99m-sestamibi.

Authors:  M K O'Connor; E Bothun; R J Gibbons
Journal:  J Nucl Cardiol       Date:  1998 May-Jun       Impact factor: 5.952

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.