Literature DB >> 1442368

Critical difference of some bovine haematological parameters.

A L Jensen1, H Houe, C G Nielsen.   

Abstract

The purpose of the present study was to calculate the critical difference between 2 analytical results for the red blood cell count (RBC), the white blood cell count (WBC), the haemoglobin concentration (Hb), and the haematocrit (PCV) in blood from Red Danish Dairy cows. The critical difference can help to judge whether the difference between 2 consecutive analytical results from the same animal may be safely ascribed to natural variation or not. To calculate the critical differences, blood samples from 20 clinically healthy lactating cows were collected once daily for 5 consecutive days. The total variance of the analytical results was divided into the component of variance between cows (S2Inter), the component of variance for days within cows (S2Intra), and the component of variance for measurements (S2Anal) using nested analysis of variance. The critical difference was then calculated from S2Intra and S2Anal as 0.61 x 10(12)/l for RBC, 2.2 x 10(9)/l for WBC, 0.79 mmol/l for Hb, and 0.07 for PCV. The critical differences may be used as guidelines to indicate potentially important changes in the parameters. However, the analytical results should not be assessed by the critical differences alone, but should also be compared to the corresponding reference intervals.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1442368      PMCID: PMC8117839     

Source DB:  PubMed          Journal:  Acta Vet Scand        ISSN: 0044-605X            Impact factor:   1.695


  9 in total

1.  Effects of intra- and interindividual variation on the appropriate use of normal ranges.

Authors:  E K Harris
Journal:  Clin Chem       Date:  1974-12       Impact factor: 8.327

2.  Intra-individual variation of some analytes in serum of patients with chronic renal failure.

Authors:  W G Hölzel
Journal:  Clin Chem       Date:  1987-05       Impact factor: 8.327

3.  Short-term and long-term intra-individual variations and critical differences of clinical chemical laboratory parameters.

Authors:  G M Costongs; P C Janson; B M Bas; J Hermans; J W van Wersch; P J Brombacher
Journal:  J Clin Chem Clin Biochem       Date:  1985-01

4.  Intra-individual variation of analytes in serum from patients with chronic liver diseases.

Authors:  W G Hölzel
Journal:  Clin Chem       Date:  1987-07       Impact factor: 8.327

5.  Components of biological variation of some serum analytes in hospitalized pregnant women.

Authors:  P J Pascoe; C S Gallagher; C G Fraser
Journal:  Clin Chem       Date:  1984-04       Impact factor: 8.327

6.  A new concept for quality control of clinical laboratory investigations in the light of clinical requirements and based on reference method values.

Authors:  D Stamm
Journal:  J Clin Chem Clin Biochem       Date:  1982-11

7.  Critical differences of clinical-chemical parameters in blood from Red Danish dairy cows.

Authors:  A L Jensen; H Houe; C G Nielsen
Journal:  Res Vet Sci       Date:  1992-01       Impact factor: 2.534

8.  Components of variance of some plasma constituents in patients with myocardial infarction.

Authors:  C G Fraser; C R Hearne
Journal:  Ann Clin Biochem       Date:  1982-11       Impact factor: 2.057

9.  Intra-individual variation of some analytes in serum of patients with insulin-dependent diabetes mellitus.

Authors:  W G Hölzel
Journal:  Clin Chem       Date:  1987-01       Impact factor: 8.327

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.