Literature DB >> 1439329

In vivo and in vitro study of the lesions produced with a computerized radiofrequency system.

F C Vinas1, L Zamorano, M Dujovny, J Z Zhao, D Hodgkinson, K L Ho, J I Ausman.   

Abstract

For many years, radiofrequency-generated lesions have been used for the treatment of pain and abnormal movements. However, the reliability of this method has been questioned because of the variation in the size of lesions produced by the electrode at different times and temperatures. A 500-kHz radiofrequency generator with different electrodes was used to determine the size of lesions, using different time and temperature exposures. A computerized feedback mechanism kept the tip temperature constant during the production of the lesion, regardless of varying tissue impedance. Eight electrodes of different size and tip characteristics were evaluated at different temperatures and time settings, both in vitro and in vivo. Graphic display of the curves in time were obtained at 65, 70, 75, 80, 85 and 90 degrees C. The effects of thermo-coagulation were studied in vitro in fresh egg whites, using time intervals of 20, 40, 60, 80 and 100 s, and in vivo, in the subcortical white matter of 20 adult New Zealand white rabbits. Animals were sacrificed after 7 days. Lesions were photographed and measured under magnification. In all cases, the coagulated masses were ellipsoid, with regular, well-demarcated borders. A two-way statistical analysis of variance was done. The coagulum size increased with higher temperatures and with larger probes. The increase was significant in both diameter and length (p = 0.001). In contrast, the use of different times at the same level of temperature showed no significant increase in most of the electrodes. There were two statistical significant time effects, for both diameter and length, with the monopolar 2-mm electrode. The use of real-time monitoring with graphic display and the feedback information provided for the computerized control of power and current allows high precision of the temperature at the electrode tip during the production of the lesion.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1439329     DOI: 10.1159/000098985

Source DB:  PubMed          Journal:  Stereotact Funct Neurosurg        ISSN: 1011-6125            Impact factor:   1.875


  6 in total

1.  A comparison between in vitro studies of protein lesions generated by brain electrodes and finite element model simulations.

Authors:  O Eriksson; J Wren; D Loyd; K Wårdell
Journal:  Med Biol Eng Comput       Date:  1999-11       Impact factor: 2.602

2.  Indications and Technique of Thoracic(2) and Thoracic(3 )Neurolysis.

Authors: 
Journal:  Curr Rev Pain       Date:  1999

3.  Analysis of temperature measurement for monitoring radio-frequency brain lesioning.

Authors:  J Wren; O Eriksson; K Wårdell; D Loyd
Journal:  Med Biol Eng Comput       Date:  2001-03       Impact factor: 3.079

4.  Analysis of radiofrequency lesions in egg whites in vitro produced by application of the Tew electrode for different temperatures and times.

Authors:  Young Suk Kwon; So Young Lim; Jong Ho Kim; Ji Su Jang; Chul Ho Kim; Kwang Jun Kwon; Jun Heum Yon
Journal:  Pain Res Manag       Date:  2015-09-10       Impact factor: 3.037

5.  The optimal radiofrequency temperature in radiofrequency thermocoagulation for idiopathic trigeminal neuralgia: A cohort study.

Authors:  Yuan-Zhang Tang; Li-Qiang Yang; Jian-Ning Yue; Xiao-Ping Wang; Liang-Liang He; Jia-Xiang Ni
Journal:  Medicine (Baltimore)       Date:  2016-07       Impact factor: 1.889

Review 6.  Long-Term Efficacy and Complications of Radiofrequency Thermocoagulation at Different Temperatures for the Treatment of Trigeminal Neuralgia.

Authors:  Tao Hong; Yuanyuan Ding; Peng Yao
Journal:  Biochem Res Int       Date:  2020-03-04
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.