Literature DB >> 1438777

Comparison of helical and serial CT with regard to three-dimensional imaging of musculoskeletal anatomy.

D R Ney1, E K Fishman, A Kawashima, D D Robertson, W W Scott.   

Abstract

To test the hypothesis that helical computed tomographic (CT) scans provide three-dimensional images as good as or better than those provided by serial CT, two objects were used to study the effects of helical CT: an angled cylindrical bone phantom and a human cadaveric femur specimen with a simulated fracture 1 mm wide. Both objects were immersed in a water bath, and a series of helical and serial CT scans were obtained with various parameters. Volumetric rendering was applied to the resultant data sets to create three-dimensional images, which three radiologists reviewed in a blinded manner to rate their fidelity, accuracy, and diagnostic usefulness. As expected, the images obtained with thin collimation and small intersection spacing or slow table movement were considered superior. Helical and serial CT data acquired with similar parameters were similar in quality, but helical CT is approximately five times faster than serial CT; hence, it is possible to use thinner collimation and obtain more sectional data with helical CT.

Entities:  

Mesh:

Year:  1992        PMID: 1438777     DOI: 10.1148/radiology.185.3.1438777

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

Review 1.  MDCT of the hand and wrist: beyond trauma.

Authors:  Shivani Ahlawat; Frank M Corl; Elliot K Fishman; Laura M Fayad
Journal:  Emerg Radiol       Date:  2014-10-10

Review 2.  Helical CT of talar fractures.

Authors:  R J Wechsler; M E Schweitzer; D Karasick; D M Deely; J B Glaser
Journal:  Skeletal Radiol       Date:  1997-03       Impact factor: 2.199

3.  Preliminary opto-electronic study on vertebral movement.

Authors:  G Vanneuville; T Kyndt; M Massaux; Y Harmand; J M Garcier; J P Monnet; M Guillot; P Cluzel; G Escande; G Poumarat
Journal:  Surg Radiol Anat       Date:  1994       Impact factor: 1.246

4.  Three-dimensional CT analysis of atlantoaxial rotation: results in the normal subject.

Authors:  J L Dumas; P Thoreux; P Attali; D Goldlust; J P Chevrel
Journal:  Surg Radiol Anat       Date:  1994       Impact factor: 1.246

5.  The quality of reconstructed 3D images in multidetector-row helical CT: experimental study involving scan parameters.

Authors:  Ji Hoon Shin; Ho Kyu Lee; Choong Gon Choi; Dae Chul Suh; Tae Hwan Lim; Weechang Kang
Journal:  Korean J Radiol       Date:  2002 Jan-Mar       Impact factor: 3.500

6.  Geometric accuracy of an acrylonitrile butadiene styrene canine tibia model fabricated using fused deposition modelling and the effects of hydrogen peroxide gas plasma sterilisation.

Authors:  Chi-Pin Hsu; Chen-Si Lin; Chun-Hao Fan; Nai-Yuan Chiang; Ching-Wen Tsai; Chun-Ming Chang; I-Li Liu
Journal:  BMC Vet Res       Date:  2020-12-09       Impact factor: 2.741

7.  Image Quality of 3rd Generation Spiral Cranial Dual-Source CT in Combination with an Advanced Model Iterative Reconstruction Technique: A Prospective Intra-Individual Comparison Study to Standard Sequential Cranial CT Using Identical Radiation Dose.

Authors:  Holger Wenz; Máté E Maros; Mathias Meyer; Alex Förster; Holger Haubenreisser; Stefan Kurth; Stefan O Schoenberg; Thomas Flohr; Christianne Leidecker; Christoph Groden; Johann Scharf; Thomas Henzler
Journal:  PLoS One       Date:  2015-08-19       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.