| Literature DB >> 1438060 |
C A Moertel1, P J Stupca, G W Dewald.
Abstract
This study was designed to test the usefulness of the common definitions for maternal cell contamination, true mosaicism, and pseudomosaicism for amniotic fluid specimens processed by in situ culture and robotic harvesting. We prospectively studied 4309 consecutive amniotic fluid specimens processed with these methods and found that 0.84 per cent had maternal cell contamination, 0.28 per cent had true mosaicism, and 5.4 per cent had pseudomosaicism. Although the frequencies of maternal cell contamination and true mosaicism were comparable to those in similar published studies, the frequency of pseudomosaicism was more than twice as high as that in previous reports. This finding is most likely not due to the method, but rather to a more accurate estimate of the actual frequency of pseudomosaicism in amniotic fluid cultures than reported heretofore. Follow-up clinical information was available on 72 per cent of the cases. In three cases of true mosaicism involving structural anomalies, the results of cytogenetic follow-up studies on the neonates were normal. None of the pseudomosaic cases involving trisomy 8, 13, 18, or 21; triple X; or monosomy X were associated with newborns who had birth defects.Entities:
Mesh:
Year: 1992 PMID: 1438060 DOI: 10.1002/pd.1970120808
Source DB: PubMed Journal: Prenat Diagn ISSN: 0197-3851 Impact factor: 3.050