Literature DB >> 1437686

The effect of multiple layers of die-spacer on crown retention.

C Passon1, R H Lambert, R L Lambert, S Newman.   

Abstract

The application of die-spacer to crown preparation dies prior to the fabrication of the cast crown is an acceptable procedure to improve the fit of the restoration. Previous studies have shown that the retention of the restoration will be improved, unchanged, or reduced when an appropriate thickness of die-spacer is used. No studies have determined the effect on retention if excessive die-spacer is used. This study evaluated the effect of increasing die-spacer thickness on the retention of cast full crowns. Cast copings were fabricated on dies coated with either 0, 4, 8, 12, or 16 coats of die-spacer, cemented on the respective teeth, and removed using an Instron Universal Testing Machine. There were no statistically significant differences (P < or = 0.05) between the mean force required to remove the cemented copings. It appears that increasing the application of die-spacer up to 16 coats (151 micrometers) does not adversely affect the retention of cemented cast copings.

Mesh:

Year:  1992        PMID: 1437686

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  5 in total

1.  Marginal discrepancy as affected by selective placement of die-spacer: an in vitro study.

Authors:  Priyam Aditya; V N V Madhav; S V Bhide; Amita Aditya
Journal:  J Indian Prosthodont Soc       Date:  2012-05-11

2.  Effect of Varying Layers of Two Die Spacers on Precementation Space of Full Coverage Restorations.

Authors:  Shivkumar A Mule; Shankar P Dange; Arun N Khalikar; Smita P Vaidya
Journal:  J Indian Prosthodont Soc       Date:  2014-05-14

3.  A comparative evaluation of application techniques of a paint-on die spacer in grooves: an in vitro study.

Authors:  K Vaishali; D Krishna Prasad; Manoj Shetty
Journal:  J Indian Prosthodont Soc       Date:  2012-10-04

4.  Impact of surface roughness of gypsum materials on adaptation of zirconia cores.

Authors:  Ki-Baek Kim; Jae-Hong Kim; Sa-Hak Kim
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

5.  Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques.

Authors:  Mi-Jung Yun; Young-Chan Jeon; Chang-Mo Jeong; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2017-02-07       Impact factor: 1.904

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.