Literature DB >> 1437069

Direct digital radiography for the detection of periodontal bone lesions.

A J Furkart1, S B Dove, W D McDavid, P Nummikoski, S Matteson.   

Abstract

In this study the diagnostic accuracy of D-speed and E-speed film in the detection of simulated periodontal bone lesions was compared with that of an electronic direct digital image receptor. Lesions of increasing depth were created in 11 human hemimandibles at the buccal cortical plate in the interproximal marginal bone area by means of 1.4 mm diameter round bursa. Specimens were imaged at each lesion stage with the use of all three receptors. Nine viewers used a 5-point rating scale to evaluate whether lesions were present or absent in the resulting images. Receiver operating characteristic curves were generated, and maximum-likelihood curve areas were calculated. The area under the curve was used as the index of diagnostic accuracy. The mean receiver operating characteristic areas for D-speed film, E-speed film, and the direct digital system were 0.745 +/- 0.038, 0.740 +/- 0.038, and 0.741 +/- 0.037, respectively. Critical ratio analysis was used to compare the means. No statistical difference was found between any of the three image receptors (p > 0.05) for the detection of simulated periodontal lesions 1.0 to 3.0 mm in depth, which suggested that the digital system performed comparably with conventional film systems.

Entities:  

Mesh:

Year:  1992        PMID: 1437069     DOI: 10.1016/0030-4220(92)90361-s

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol        ISSN: 0030-4220


  5 in total

1.  Evaluation of simulated periodontal defects via various radiographic methods.

Authors:  Ayse Zeynep Zengin; Pinar Sumer; Peruze Celenk
Journal:  Clin Oral Investig       Date:  2015-02-14       Impact factor: 3.573

2.  Comparison of diagnostic accuracy of conventional intraoral periapical and direct digital radiographs in detecting interdental bone loss.

Authors:  S R Ashwinirani; Girish Suragimath; H P Jaishankar; Prasad Kulkarni; Shobha C Bijjaragi; Varsha Ajit Sangle
Journal:  J Clin Diagn Res       Date:  2015-02-01

3.  Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study.

Authors:  Rafael Scaf de Molon; Juliana Aparecida Najarro Dearo Morais-Camillo; Celso Eduardo Sakakura; Mauricio Goncalves Ferreira; Leonor Castro Monteiro Loffredo; Gulnara Scaf
Journal:  Imaging Sci Dent       Date:  2012-12-23

4.  Conventional versus digital radiography in detecting root canal type in maxillary premolars: an in vitro study.

Authors:  Mahkameh Moshfeghi; Soodabeh Sadat Sajadi; Sepideh Sajadi; Majid Shahbazian
Journal:  J Dent (Tehran)       Date:  2013-01-31

5.  Comparison between inverted and unprocessed digitized radiographic imaging in periodontal bone loss measurements.

Authors:  Gulnara Scaf; Olívia Morihisa; Leonor de Castro Monteiro Loffredo
Journal:  J Appl Oral Sci       Date:  2007-12       Impact factor: 2.698

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.