Literature DB >> 1435183

Accuracy of RPE from graded exercise to establish exercise training intensity.

S C Glass1, R G Knowlton, M D Becque.   

Abstract

The purpose of this investigation was to examine the accuracy of an exercise intensity prescription based upon perceptual responses obtained during a graded exercise test. Fifteen physically active men completed a graded exercise test (GXT) on a motor driven treadmill. Heart rate (HR), oxygen uptake (VO2), and RPE were measured each minute. An RPE intensity prescription was calculated as 75% of heart rate reserve from the GXT heart rate and RPE data. A minimum of 48 h later the subjects completed 10 min of exercise (EXT) on a level treadmill at the prescribed RPE. The subjects set the treadmill speed to elicit an exercise intensity equal to the prescribed perception of effort. There were significant mean differences (P < 0.05) in heart rate between the GXT (161.8 +/- 1.3) and EXT (154.9 +/- 4.5). However, by minute 6 the subjects were within four beats.min-1 of the target heart rate. There were no significant differences (P > 0.05) between GXT and EXT for VO2 (36.1 +/- 5.2, 33.1 +/- 6.4) and VE (64.1 +/- 10.8, 58.4 +/- 13.5) respectively. The present investigation demonstrates that a subject's perceptual response to a GXT can be used to accurately prescribe exercise intensity during level treadmill running. The intensity selected was within a typical range used for exercise prescription. The advantage of RPE as a method of exercise prescription is that an individual does not need to stop during exercise and measure a heart rate, but can make pace adjustments while exercising based solely upon the perception of effort.

Entities:  

Mesh:

Year:  1992        PMID: 1435183

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  23 in total

1.  Regulating intensity using perceived exertion during extended exercise periods.

Authors:  Jie Kang; Jay R Hoffman; Heather Walker; Edward C Chaloupka; Alan C Utter
Journal:  Eur J Appl Physiol       Date:  2003-04-24       Impact factor: 3.078

2.  A perceptually regulated, graded exercise test predicts peak oxygen uptake during treadmill exercise in active and sedentary participants.

Authors:  Roger Eston; Harrison Evans; James Faulkner; Danielle Lambrick; Harran Al-Rahamneh; Gaynor Parfitt
Journal:  Eur J Appl Physiol       Date:  2012-01-26       Impact factor: 3.078

3.  Self-regulation of exercise intensity by estimated time limit scale.

Authors:  M Garcin; J Coquart; J Salleron; N Voy; R Matran
Journal:  Eur J Appl Physiol       Date:  2011-10-19       Impact factor: 3.078

4.  RPE-lactate dissociation during extended cycling.

Authors:  J M Green; J R McLester; T R Crews; P J Wickwire; R C Pritchett; A Redden
Journal:  Eur J Appl Physiol       Date:  2005-02-09       Impact factor: 3.078

5.  The validity of predicting maximal oxygen uptake from a perceptually-regulated graded exercise test.

Authors:  Roger G Eston; Kevin L Lamb; Gaynor Parfitt; Nicholas King
Journal:  Eur J Appl Physiol       Date:  2005-04-07       Impact factor: 3.078

6.  Regulating intensity using perceived exertion: effect of exercise duration.

Authors:  Jie Kang; Edward C Chaloupka; Gregory B Biren; M Alysia Mastrangelo; Jay R Hoffman
Journal:  Eur J Appl Physiol       Date:  2008-11-12       Impact factor: 3.078

7.  Effect of exercise intensity on differentiated and undifferentiated ratings of perceived exertion during cycle and treadmill exercise in recreationally active and trained women.

Authors:  Melinda R Bolgar; Carol E Baker; Fredric L Goss; Elizabeth Nagle; Robert J Robertson
Journal:  J Sports Sci Med       Date:  2010-12-01       Impact factor: 2.988

8.  The use of ratings of perceived exertion for regulating exercise levels in rowing ergometry.

Authors:  H E Marriott; K L Lamb
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

9.  The place of perceived exertion ratings in exercise prescription for cardiac transplant patients before and after training.

Authors:  R J Shephard; T Kavanagh; D J Mertens; M Yacoub
Journal:  Br J Sports Med       Date:  1996-06       Impact factor: 13.800

10.  Validity of Ratings of Perceived Exertion in Patients with Type 2 Diabetes.

Authors:  Jessica L Unick; Sarah Gaussoin; Judy Bahnson; Richard Crow; Jeff Curtis; Tina Killean; Judith G Regensteiner; Kerry J Stewart; Rena R Wing; John M Jakicic
Journal:  J Nov Physiother Phys Rehabil       Date:  2014-07-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.