Use of luting agents with an implant system: Part I.

L C Breeding1, D L Dixon, M T Bogacki, J D Tietge.   

Abstract

When removal of the provisionally cemented superstructure from a cemented abutment becomes necessary, the retentive strengths of the abutment/fixture and superstructure/abutment luting agents become important considerations. This study compared the retentive strengths of castings cemented to machined titanium implant abutments and to a human premolar with three provisional luting agents. Also tested were the retentive strengths of cast noble metal implant abutments cemented into titanium fixtures with three permanent luting agents both dry and after storage in 0.9% physiologic saline for 30 days at 37 degrees C. No significant differences (alpha < 0.05) were noted in retentive values between the cemented castings on the titanium abutments and the natural tooth. The Temp Bond zinc oxide-eugenol luting agent exhibited a lower mean retentive strength than the IRM reinforced zinc oxide-eugenol and Life calcium hydroxide luting agents. Ketac Cem glass-ionomer cemented abutments that were stored in saline exhibited a significantly higher mean retentive strength than abutments cemented with either Core Paste or Resiment resin luting agents. On the basis of results from this study, it may be concluded that superstructures provisionally cemented with Temp Bond, IRM, or Life luting agents may be removed from implant abutments without disturbing the abutment/fixture or implant bond.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1432793     DOI: 10.1016/0022-3913(92)90194-f

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  18 in total

1.  A modified technique for extraoral cementation of implant retained restorations for preventing excess cement around the margins.

Authors:  Emir Yuzbasioglu
Journal:  J Adv Prosthodont       Date:  2014-04-22       Impact factor: 1.904

2.  Comparison of the effect of implant abutment surface modifications on retention of implant-supported restoration with a polymer based cement.

Authors:  Nabaprakash Sahu; Namratha Lakshmi; N S Azhagarasan; Yoshaskam Agnihotri; Manoj Rajan; Ramasubramanian Hariharan
Journal:  J Clin Diagn Res       Date:  2014-01-12

3.  Effect of Abutment Height on Retention of Single Cement-retained, Wide- and Narrow-platform Implant-supported Restorations.

Authors:  Fariba Saleh Saber; Nader Abolfazli; Sara Nuroloyuni; Sohleh Khodabakhsh; Mehran Bahrami; Reza Nahidi; Somaieh Zeighami
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2012-09-01

4.  Retentiveness of implant-supported metal copings using different luting agents.

Authors:  Farahnaz Nejatidanesh; Omid Savabi; Maziar Ebrahimi; Ghazal Savabi
Journal:  Dent Res J (Isfahan)       Date:  2012-01

5.  The Effects of New Design of Access Hole on Porcelain Fracture Resistance of Implant-Supported Crowns.

Authors:  Reza Derafshi; Mitra Farzin; Masoumeh Taghva; Hossein Heidary; Berivan Atashkar
Journal:  J Dent (Shiraz)       Date:  2015-03

6.  Knowledge and practice of implant-retained restorations among dental students in Saudi Arabia.

Authors:  Fahim Vohra; Altaf Hussain Shah; Mohammad Sohail Zafar; Zaheer Kola
Journal:  Pak J Med Sci       Date:  2015 Jul-Aug       Impact factor: 1.088

7.  Effect of abutment modification and cement type on retention of cement-retained implant supported crowns.

Authors:  Mitra Farzin; Kianoosh Torabi; Ahmad Hasan Ahangari; Reza Derafshi
Journal:  J Dent (Tehran)       Date:  2014-05-31

8.  Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro.

Authors:  Felix Dähne; Heike Meißner; Klaus Böning; Christin Arnold; Ralf Gutwald; Elisabeth Prause
Journal:  Int J Implant Dent       Date:  2021-07-20

9.  A comparison of retentive strength of implant cement depending on various methods of removing provisional cement from implant abutment.

Authors:  Eun-Cheol Keum; Soo-Yeon Shin
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

10.  Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation.

Authors:  Matthias Rödiger; Sven Rinke; Fenja Ehret-Kleinau; Franziska Pohlmeyer; Katharina Lange; Ralf Bürgers; Nikolaus Gersdorff
Journal:  J Adv Prosthodont       Date:  2014-06-24       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.