Literature DB >> 1431916

Clinical and radiographic analysis of the uncemented LSF total hip arthroplasty.

R L Barrack1, R D Lebar.   

Abstract

Forty-nine consecutive uncemented porous-coated LSF total hip prostheses were implanted in 41 patients and studied prospectively. Clinical rating as described by Harris was performed preoperatively, at 6 months and 1 year postoperatively, and annually thereafter. Anteroposterior and lateral radiographs were obtained preoperatively, immediately postoperatively, at 6 and 12 months, and annually thereafter. At the most recent follow-up visit, patients were evaluated clinically and radiographically utilizing the format recently recommended by the Hip Society. A patient satisfaction questionnaire was also completed. The follow-up period averaged 37 months (range, 24-48 months). Preoperative hip scores averaged 38 (range, 18-68) and improved to 93 at the most recent follow-up visit (range, 76-100). The incidence of mild pain was 14% at 1 year and 4% at 2 years or more. The incidence of limp was 16% slight and 8% moderate at 1 year, and 12% slight and 2% moderate at 2 years or more. Surgical fit was objectively graded as excellent in 61%, good in 33%, and poor in 6%. The authors were unable to correlate surgical fit with clinical scores or radiographic findings. According to radiographic criteria, all components were judged to be stable and 86% were judged to demonstrate objective signs of osseointegration. Patient satisfaction with the procedure was 100%. All patients stated that the procedure increased their function and decreased their pain and need for medication. Compared to a normal hip, in terms of symptoms and function, the patients rated their postoperative hip at 85% (range, 50-100%). Compared to their level of activity before their hip was symptomatic, they rated their current activity level as 83% (range, 50-100%).

Entities:  

Mesh:

Year:  1992        PMID: 1431916     DOI: 10.1016/s0883-5403(07)80024-6

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  2 in total

1.  Pedestal sign in cementless total hip replacement.

Authors:  F Agathangelidis; A Boutsiadis; G Petsatodis
Journal:  Hippokratia       Date:  2014 Oct-Dec       Impact factor: 0.471

2.  High Subsidence Rate After Primary Total Hip Arthroplasty Using a Zweymüller-type Noncemented Implant With a Matte Surface.

Authors:  Toshiyuki Kawai; Koji Goto; Yutaka Kuroda; Yaichiro Okuzu; Shuichi Matsuda
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2022-06-07
  2 in total