Literature DB >> 143186

On the molecular composition and physico-chemical properties of the pseudo-exfoliation material.

M Davanger.   

Abstract

The protein tracer peroxidase has been found to be excluded from pseudoexfoliation (PE) material. But after the treatment of the PE material with cetylpyridinium-chloride, peroxidase was found to penetrate into the material. This observation seems to support the concept that the PE material is a gel of proteoglycans, from which peroxidase is excluded by an excluded volume effect. Microperoxidase was found to penetrate into the superficial parts of the (untreated) PE material, and to be regularly distributed according to two different patterns: 1) along the PE fibrils, and 2) along lines in the interfibrillar matrix; lines which can not be seen without the presence of microperoxidase. At both locations the microperoxidase reaction product was found at regular intervals, with spacings of about 53 nm. The interpretation is that both the fibrils and the interfibrillar matrix are composed of the same kind of long extended linear proteoglycan complexes, but with a different arrangement and density.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 143186     DOI: 10.1111/j.1755-3768.1977.tb05660.x

Source DB:  PubMed          Journal:  Acta Ophthalmol (Copenh)        ISSN: 0001-639X


  6 in total

1.  Studies on the pseudo-exfoliation material: a review.

Authors:  M Davanger
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1978-11-08

2.  The cornea in exfoliation syndrome.

Authors:  M Stefaniotou; C Kalogeropoulos; N Razis; K Psilas
Journal:  Doc Ophthalmol       Date:  1992       Impact factor: 2.379

3.  The environment and the lens.

Authors:  H R Taylor
Journal:  Br J Ophthalmol       Date:  1980-05       Impact factor: 4.638

4.  Fluorescein angiography and fluorophotometry of the iris in pseudoexfoliation of the lens capsule.

Authors:  A M Brooks; W E Gillies
Journal:  Br J Ophthalmol       Date:  1983-04       Impact factor: 4.638

5.  Cataract extraction complicated by capsular glaucoma.

Authors:  A J Dark
Journal:  Br J Ophthalmol       Date:  1979-07       Impact factor: 4.638

Review 6.  Changes in peri-ocular anatomy and physiology in pseudoexfoliation syndrome (Review).

Authors:  Efstathios T Detorakis; Georgios Bontzos; Eleni E Drakonaki; Demetrios A Spandidos
Journal:  Exp Ther Med       Date:  2021-04-19       Impact factor: 2.447

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.