Literature DB >> 1429984

Determination of 4,4'-methylenedianiline in hydrolysed human urine by micro liquid chromatography with ultraviolet detection.

P Brunmark1, P Persson, G Skarping.   

Abstract

4,4'-Methylenedianiline was determined in human urine by micro liquid chromatography with ultraviolet detection. The combination of a thorough work-up and the high mass sensitivity of micro liquid chromatography gave the method very high sensitivity. Derivatization with pentafluoropropionic anhydride enhanced the resolution of the 4,4'-dimethylenedianiline peak. The detection limit, defined as blank plus three times the standard deviation of the blank, was 2 nmol/l of urine, for 10-microliters injection volumes. The detection limit, defined as three times the noise, was about ten times better. The within- and between-assay coefficients of variation were 4 and 6%, respectively, for samples containing 40 nmol/l. The method was applied for the monitoring of excreted 4,4'-methylenedianiline in urine, during epicutaneous skin hypersensitivity testing (patch testing).

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1429984     DOI: 10.1016/0378-4347(92)80403-d

Source DB:  PubMed          Journal:  J Chromatogr


  6 in total

1.  Biological monitoring of workers exposed to 4,4'-methylenediphenyl diisocyanate (MDI) in 19 French polyurethane industries.

Authors:  A Robert; P Ducos; J M Francin; P Marsan
Journal:  Int Arch Occup Environ Health       Date:  2006-10-24       Impact factor: 3.015

2.  Biological monitoring of exposure to 1,5-naphthalene diisocyanate and 4,4'-methylenediphenyl diisocyanate.

Authors:  C J Sennbro; C H Lindh; C Mattsson; B A G Jönsson; H Tinnerberg
Journal:  Int Arch Occup Environ Health       Date:  2006-02-28       Impact factor: 3.015

3.  Determination of urinary 4,4'-methylenedianiline and its acetylated metabolites by solid-phase extraction and HPLC analysis with UV and electrochemical detection.

Authors:  A Robert; P Ducos; J M Francin
Journal:  Int Arch Occup Environ Health       Date:  1995       Impact factor: 3.015

4.  Biomonitoring of 4,4'-methylene dianiline by measurement in hydrolysed urine and plasma after epicutaneous exposure in humans.

Authors:  P Brunmark; M Bruze; S Skerfving; G Skarping
Journal:  Int Arch Occup Environ Health       Date:  1995       Impact factor: 3.015

5.  4,4'-Methylenedianiline in hydrolysed serum and urine from a worker exposed to thermal degradation products of methylene diphenyl diisocyanate elastomers.

Authors:  G Skarping; M Dalene; M Littorin
Journal:  Int Arch Occup Environ Health       Date:  1995       Impact factor: 3.015

6.  Development of immunoassays for biomonitoring of hexamethylene diisocyanate exposure.

Authors:  R Lemus; L Lukinskeine; M E Bier; A V Wisnewski; C A Redlich; M H Karol
Journal:  Environ Health Perspect       Date:  2001-11       Impact factor: 9.031

  6 in total