| Literature DB >> 1427416 |
H Oosterhof1, K Dijkstra, J G Aarnoudse.
Abstract
Pulsed-wave Doppler ultrasound was used to evaluate the influence of Braxton Hicks' contractions on flow velocity waveforms in the uterine arteries. Flow velocity waveforms were obtained from a standardized site, at the crossing of the uterine artery with the external iliac artery near the uterine wall. Doppler signals were recorded in 16 healthy near-term nulliparous pregnant women. During Braxton Hicks' contractions, a considerable increase in pulsatility index (PI) was found in the uterine arteries increasing from 0.71 +/- 0.21 (mean +/- SD) to 1.14 +/- 0.67 (p < 0.005). Maternal heart rate decreased slightly but significantly during contractions. Despite the high PI values that were found during Braxton Hicks' contractions, a diastolic notch in the flow velocity waveform was never noticed. The findings indicate that during Braxton Hicks' contractions, resistance to blood flow in the uteroplacental circulation is considerably increased.Entities:
Mesh:
Year: 1992 PMID: 1427416 DOI: 10.1159/000292750
Source DB: PubMed Journal: Gynecol Obstet Invest ISSN: 0378-7346 Impact factor: 2.031