Literature DB >> 1424874

Rhodotorula rubra contamination in fiberoptic bronchoscopy.

W L Whitlock1, R A Dietrich, E H Steimke, M F Tenholder.   

Abstract

Rhodotorula rubra was recovered in 18 bronchoscopic specimens from 15 patients from May to November 1987. One hundred and twenty-one bronchoscopies were performed during that period by two bronchoscopists (W. W.; R.D.) at Letterman Army Medical Center in San Francisco. Isolation of R rubra occurred in 11 bronchoalveolar lavage (BAL) specimens, four bronchial washes, and three transbronchial biopsies. Clinical infection was not present in any of these patients, although five were immunocompromised hosts. After a stepwise infection control review of the laboratory, the bronchoscopy suite, bronchoscopists, and the fiberoptic bronchoscope failed to recover the organism, a systematic evaluation of the cleaning procedure was undertaken. We discovered that replacement of the suction valve and the rubber biopsy valve on the biopsy channel immediately after cleaning allowed moisture to accumulate in these areas. Removal of both the suction valve and biopsy valve during periods of nonuse resulted in adequate drying of the biopsy channel and eradication of contamination from December 1987 to May 1990 (350 bronchoscopies). Epidemiologic and infection control surveillance is critical for bronchoscopy, especially when possible pathogens are recovered by BAL in the immunocompromised patient.

Entities:  

Mesh:

Year:  1992        PMID: 1424874     DOI: 10.1378/chest.102.5.1516

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  4 in total

1.  Catheter-related sepsis due to Rhodotorula glutinis.

Authors:  Po-Ren Hsueh; Lee-Jene Teng; Shen-Wu Ho; Kwen-Tay Luh
Journal:  J Clin Microbiol       Date:  2003-02       Impact factor: 5.948

Review 2.  Could Histoplasma capsulatum Be Related to Healthcare-Associated Infections?

Authors:  Laura Elena Carreto-Binaghi; Lisandra Serra Damasceno; Nayla de Souza Pitangui; Ana Marisa Fusco-Almeida; Maria José Soares Mendes-Giannini; Rosely Maria Zancopé-Oliveira; Maria Lucia Taylor
Journal:  Biomed Res Int       Date:  2015-05-27       Impact factor: 3.411

Review 3.  American College of Chest Physicians and American Association for Bronchology [corrected] consensus statement: prevention of flexible bronchoscopy-associated infection.

Authors:  Atul C Mehta; Udaya B S Prakash; Robert Garland; Edward Haponik; Leonard Moses; William Schaffner; Gerard Silvestri
Journal:  Chest       Date:  2005-09       Impact factor: 9.410

4.  Evidence-based spectrum of antimicrobial activity for disinfection of bronchoscopes.

Authors:  Constanze Wendt; Birgit Kampf
Journal:  J Hosp Infect       Date:  2008-10       Impact factor: 3.926

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.