Literature DB >> 1423950

Intravascular ultrasound evaluation of the effect of rotational atherectomy in obstructive atherosclerotic coronary artery disease.

G S Mintz1, B N Potkin, G Keren, L F Satler, A D Pichard, K M Kent, J J Popma, M B Leon.   

Abstract

BACKGROUND: High-speed rotational atherectomy uses a diamond-coated, elliptical burr to abrade occlusive atherosclerosis, especially noncompliant calcified plaque. METHODS AND
RESULTS: Intravascular ultrasound (IVUS) was used to analyze 28 patients after atherectomy. Arteries treated and imaged were left main (three), left anterior descending (12), left circumflex (five), right coronary (seven), and saphenous vein graft (one). Twenty patients had adjunct balloon angioplasty. Twenty-two (79%) target lesions were calcified; the intimal arc of calcium was 160 +/- 126 degrees (range, 0-360 degrees). After atherectomy, the intima-lumen interface was unusually distinct and circular. The lumen was larger than the largest burr used for both stand-alone (1.19 +/- 0.19-fold the largest burr size) and adjunct balloon procedures (1.30 +/- 0.15-fold the largest burr). Three-dimensional reconstruction of the ultrasound images showed a smooth lumen, especially in calcified plaque. Deviations from cylindrical geometry occurred only in areas of soft plaque or superficial tissue disruption of calcified plaque. Five patients were studied before and after rotational atherectomy. IVUS showed an increase in lumen size, a decrease in plaque-plus-media area and in arc of target lesion calcification, and no change in target lesion external elastic membrane cross-sectional area.
CONCLUSIONS: Rotational atherectomy causes atheroablation with only moderate evidence of barotrauma in heavily calcified arteries, even after adjunct balloon angioplasty. The lumen is cylindrical, especially in areas of calcified plaque, and somewhat larger than the largest burr tip used.

Entities:  

Mesh:

Year:  1992        PMID: 1423950     DOI: 10.1161/01.cir.86.5.1383

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  13 in total

1.  A case of active peri-stent inflammation after sirolimus-eluting stent implantation.

Authors:  Takafumi Kurosawa; Jun-Ichi Kotani; Taka-aki Matsuyama; Hatsue Ishibashi-Ueda
Journal:  Heart Vessels       Date:  2014-01-10       Impact factor: 2.037

2.  Utility of intravascular ultrasound in peripheral interventions.

Authors:  R A White; C E Donayre; G E Kopchok; I Walot; C M Mehringer
Journal:  Tex Heart Inst J       Date:  1997

Review 3.  [Pathophysiology and therapeutic concepts in coronary restenosis].

Authors:  H G Klues; P W Radke; R Hoffmann; J vom Dahl
Journal:  Herz       Date:  1997-12       Impact factor: 1.443

Review 4.  Intracoronary ultrasound: current state of the art.

Authors:  P P Kearney; I R Starkey; G R Sutherland
Journal:  Br Heart J       Date:  1995-05

5.  Why the controversy about electron beam computed tomographic screening for coronary atherosclerosis?

Authors:  R C Detrano
Journal:  Br Heart J       Date:  1994-10

6.  Intravascular ultrasound: an inside view.

Authors:  P G Yock; W L Mullen; P J Fitzgerald
Journal:  Br Heart J       Date:  1994-08

Review 7.  How Do We Treat Complex Calcified Coronary Artery Disease?

Authors:  Paul N Fiorilli; Saif Anwaruddin
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-12

8.  Coronary artery compliance and adaptive vessel remodelling in patients with stable and unstable coronary artery disease.

Authors:  A Jeremias; C Spies; N A Herity; E Pomerantsev; P G Yock; P J Fitzgerald; A C Yeung
Journal:  Heart       Date:  2000-09       Impact factor: 5.994

9.  Intravascular ultrasound assessment of the effects of rotational atherectomy in calcified coronary artery lesions.

Authors:  Sung Sik Kim; Myong Hwa Yamamoto; Akiko Maehara; Novalia Sidik; Kohei Koyama; Colin Berry; Keith G Oldroyd; Gary S Mintz; Margaret McEntegart
Journal:  Int J Cardiovasc Imaging       Date:  2018-04-16       Impact factor: 2.357

Review 10.  Intracoronary ultrasound.

Authors:  C Hammond; J P Causer; R A Perry
Journal:  Postgrad Med J       Date:  1998-08       Impact factor: 2.401

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.