Literature DB >> 1423575

Measurements of central blood vessels in infants and children: normal values.

C Steinberg1, D J Weinstock, J P Gold, D A Notterman.   

Abstract

In order to provide physicians interpreting vascular radiographic studies with normal data regarding central blood vessel size in children and to facilitate the design and adaptation of intravascular devices for pediatric use, we measured lengths and diameters of central blood vessels in 141 radiographic studies in 136 children. The diameters of the following vessels were determined: right and left internal jugular veins and common carotid arteries; the inferior vena cava and the descending thoracic aorta; right and left iliac veins; and right and left femoral veins and arteries. In addition, the lengths of the inferior vena cava and the descending aorta were also determined. Blood vessel dimensions were highly correlated with age, height, weight, and body surface area. The linear regression equations for each measured dimension against age, weight, height, and surface area are provided, along with a table of predicted vessel size as a function of age.

Entities:  

Mesh:

Year:  1992        PMID: 1423575     DOI: 10.1002/ccd.1810270308

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  12 in total

1.  Ultrasound-guided internal jugular vein catheterization in critically ill pediatric patients.

Authors:  Eu Jeen Yang; Hyeong Seok Ha; Young Hwa Kong; Sun Jun Kim
Journal:  Korean J Pediatr       Date:  2015-04-22

2.  Central venous catheter placement in children: a prospective study of complications in a Brazilian public hospital.

Authors:  Paulo Custódio F Cruzeiro; Paulo Augusto M Camargos; Marcelo E Miranda
Journal:  Pediatr Surg Int       Date:  2006-05-05       Impact factor: 1.827

3.  Vascular ultrasound in pediatrics: utility and application of location and measurement of jugular and femoral vessels.

Authors:  J M López Álvarez; O Pérez Quevedo; L Santana Cabrera; C Rodríguez Escot; T Ramírez Lorenzo; J M Limiñana Cañal; J F Loro Ferrer
Journal:  J Med Ultrason (2001)       Date:  2017-12-18       Impact factor: 1.314

Review 4.  Continuous arterial gas monitoring: initial experience with the Paratrend 7 in children.

Authors:  I K Weiss; S Fink; S Edmunds; R Harrison; K Donnelly
Journal:  Intensive Care Med       Date:  1996-12       Impact factor: 17.440

5.  Stent treatment for coarctation of the aorta: intermediate term follow up and technical considerations.

Authors:  B D Thanopoulos; L Hadjinikolaou; G N Konstadopoulou; G S Tsaousis; F Triposkiadis; P Spirou
Journal:  Heart       Date:  2000-07       Impact factor: 5.994

6.  Safety and efficacy of ultrasound assistance during internal jugular vein cannulation in neurosurgical infants.

Authors:  M Lamperti; D Caldiroli; P Cortellazzi; D Vailati; A Pedicelli; F Tosi; M Piastra; D Pietrini
Journal:  Intensive Care Med       Date:  2008-07-11       Impact factor: 17.440

Review 7.  Pharmacokinetics of nanotechnology-based formulations in pediatric populations.

Authors:  Venkata K Yellepeddi; Andrea Joseph; Elizabeth Nance
Journal:  Adv Drug Deliv Rev       Date:  2019-09-05       Impact factor: 15.470

Review 8.  Clinical review: alternative vascular access techniques for continuous hemofiltration.

Authors:  Joseph V DiCarlo; Scott R Auerbach; Steven R Alexander
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

9.  Femoral vein size in newborns and infants: preliminary investigation.

Authors:  O A Akingbola; J Nielsen; R L Hopkins; E M Frieberg
Journal:  Crit Care       Date:  2000-03-03       Impact factor: 9.097

10.  Vascular ultrasound in pediatrics: estimation of depth and diameter of jugular and femoral vessels.

Authors:  J M López Álvarez; O Pérez Quevedo; L Santana Cabrera; C Rodríguez Escot; J F Loro Ferrer; T Ramírez Lorenzo; J M Limiñana Cañal
Journal:  J Ultrasound       Date:  2017-11-14
View more