Literature DB >> 1422709

Vein compliance: a preoperative indicator of vein morphology and of veins at risk of vascular graft stenosis.

A H Davies1, T R Magee, R N Baird, E Sheffield, M Horrocks.   

Abstract

Compliance measurements of 53 long saphenous veins before femorodistal bypass have been performed using a duplex scanner with venous occlusion for distension. These have been compared with the histological features of the veins. There was significantly more moderate or severe focal hyperplasia and circular muscle hypertrophy in distal long saphenous vein than in its proximal counterpart (P < 0.01 and P < 0.05 respectively). The mean (95 per cent confidence interval) compliance of distal vein with moderate or severe hyperplasia was 0.16 (0.13-0.19) compared with 0.29 (0.22-0.36) for that with no, minimal or mild hyperplasia (P = 0.001). The mean compliance of distal vein with moderate or severe muscle hypertrophy was 0.19 (0.17-0.21) and of vein with no, minimal or mild hypertrophy 0.25 (0.21-0.29) (P = 0.14). The mean lowest compliance in seven patients who developed stenosis was 0.10 (0.07-0.13) compared with 0.21 (0.16-0.26) in the rest (P < 0.001). Preoperative measurement of vein compliance can be used to identify vein with marked pre-existing intimal hyperplasia and as a predictor of future graft stenosis.

Entities:  

Mesh:

Year:  1992        PMID: 1422709     DOI: 10.1002/bjs.1800791011

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  10 in total

1.  A functional and histopathological comparison of proximal and distal saphenous vein contractility and morphology.

Authors:  Ilhan Golbasi; Arda Tasatargil; Nazif Hikmet Aksoy; Gulay Sadan; Edibe Karasu; Cengiz Turkay; Omer Bayezid
Journal:  Tex Heart Inst J       Date:  2005

2.  Effects of upstream shear forces on priming of platelets for downstream adhesion and activation.

Authors:  Shekh M Rahman; Colin D Eichinger; Vladimir Hlady
Journal:  Acta Biomater       Date:  2018-04-11       Impact factor: 8.947

Review 3.  Vein quality in infrainguinal revascularisation: assessment by angioscopy and histology.

Authors:  Y G Wilson
Journal:  Ann R Coll Surg Engl       Date:  1998-01       Impact factor: 1.891

4.  Biaxial Stretch Improves Elastic Fiber Maturation, Collagen Arrangement, and Mechanical Properties in Engineered Arteries.

Authors:  Angela H Huang; Jenna L Balestrini; Brooks V Udelsman; Kevin C Zhou; Liping Zhao; Jacopo Ferruzzi; Barry C Starcher; Michael J Levene; Jay D Humphrey; Laura E Niklason
Journal:  Tissue Eng Part C Methods       Date:  2016-06       Impact factor: 3.056

5.  Vein factors that affect the outcome of femorodistal bypass.

Authors:  A H Davies
Journal:  Ann R Coll Surg Engl       Date:  1995-01       Impact factor: 1.891

6.  The effects of aging on the intimal region of the human saphenous vein: insights from multimodal microscopy and quantitative image analysis.

Authors:  Cindy Fonseca; Douglas J Taatjes; Peter Callas; Frank Ittleman; Edwin G Bovill
Journal:  Histochem Cell Biol       Date:  2012-05-23       Impact factor: 4.304

7.  Pressure applied during surgery alters the biomechanical properties of human saphenous vein graft.

Authors:  Necla Ozturk; Nehir Sucu; Ulku Comelekoglu; Banu Coskun Yilmaz; Barlas Naim Aytacoglu; Ozden Vezir
Journal:  Heart Vessels       Date:  2012-03-29       Impact factor: 2.037

8.  A Robust Method to Generate Mechanically Anisotropic Vascular Smooth Muscle Cell Sheets for Vascular Tissue Engineering.

Authors:  Daniel E Backman; Bauer L LeSavage; Shivem B Shah; Joyce Y Wong
Journal:  Macromol Biosci       Date:  2017-02-16       Impact factor: 4.979

Review 9.  Adaptive changes in autogenous vein grafts for arterial reconstruction: clinical implications.

Authors:  Christopher D Owens
Journal:  J Vasc Surg       Date:  2009-10-17       Impact factor: 4.268

10.  A microstructurally motivated model of the mechanical behavior of tissue engineered blood vessels.

Authors:  Shannon L M Dahl; Megann E Vaughn; Jin-Jia Hu; Niels J B Driessen; Frank P T Baaijens; Jay D Humphrey; Laura E Niklason
Journal:  Ann Biomed Eng       Date:  2008-08-22       Impact factor: 3.934

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.