[The use of the T-Scan system in occlusal diagnosis].

A Dees1, K Kess, P Proff, S Schneider.   

Abstract

The present study examines the T-Scan reproduction system used in occlusal diagnosis. The system represents a major technical innovation in functional diagnostics. Nevertheless, various aspects of it still require improvement. Amplifying or confirming the results of previous studies, the following observations are intended to indicate how the system might be improved, and how it can be reliably used at present: The reproduction afforded by the sensor as situated in the mouth is insufficient. Exact reproduction of the topography of the occlusal contacts is not possible. Reproducibility of the temporal sequence of the contacts is slight. The registering of dental functional movements can give rise to errors of interpretation. Threshold values for the registration of contact points in the system's pressure mode are uneven. The relative reproduction of different impressions is unreliable. Since in the system's pressure-mode early contacts cannot be distinguished from strong physiological contacts, in clinical practice the former must first be identified using the time-mode.

Mesh:

Year:  1992        PMID: 1420658

Source DB:  PubMed          Journal:  Dtsch Zahn Mund Kieferheilkd Zentralbl


  4 in total

1.  Precision of an instrumentation-based method of analyzing occlusion and its resulting distribution of forces in the dental arch.

Authors:  Bernd Koos; Arnim Godt; Christine Schille; Gernot Göz
Journal:  J Orofac Orthop       Date:  2010-11-17       Impact factor: 1.938

2.  Evaluation of occlusal function during orthognathic therapy : A prospective clinical trial using a digital registration method.

Authors:  Bernhard Wiechens; Anja Quast; Daniela Klenke; Phillipp Brockmeyer; Henning Schliephake; Philipp Meyer-Marcotty
Journal:  J Orofac Orthop       Date:  2022-02-28       Impact factor: 1.938

3.  Assessment of occlusion with the T-Scan system in patients undergoing orthognathic surgery.

Authors:  Jimoh Olubanwo Agbaje; Elke Van de Casteele; Ahmed S Salem; Dickson Anumendem; Eman Shaheen; Yi Sun; Constantinus Politis
Journal:  Sci Rep       Date:  2017-07-13       Impact factor: 4.379

4.  Occlusion in the digital era: a report on 3 cases.

Authors:  Smaranda Buduru; Anca Mesaros; Daniel Talmaceanu; Oana Baru; Raul Ghiurca; Raluca Cosgarea
Journal:  Med Pharm Rep       Date:  2019-12-15